CS-MC95KE, CS-MC125KE, CS-MC76KE, CS-MC126KE, CU-MC145KE, CU-MC185KE, CU-MC205KE, CU-MC245KE, CU-MC196KE - Panasonic Air Conditioner Service Manual (repair manual). Page 91

Read Panasonic CS-MC95KE / CS-MC125KE / CS-MC76KE / CS-MC126KE / CU-MC145KE / CU-MC185KE / CU-MC205KE / CU-MC245KE / CU-MC196KE Service Manual online

 2. Remove the Fan Motor by:-
  − 
Release the Fan motor leadwire by pressing the
hook at the center of the connector. (
  − 
Then remove the particular piece that holding the
fan motor by pressing the tab. ()
  − 
Remove the discharge grille and then the drain
hose. ()
  − 
Finally remove the fan motor by removing the screw.
()
  − 
REMINDER - To reinstall the fan motor, adjust the
connector of the fan motor as .
Fig. 4
Fig. 5
91
CS-MC95KE CU-MC145KE / CS-MC95KE CU-MC185KE / CS-MC95KE CU-3MC205KE / CS-MC125KE CU-MC245KE / CS-MC76KE / CS-MC126KE CU-MC196KE
Page of 126
Display