– 29 –
ORDER NO. MAC9807010C3
CS-MC90KH
3-way Valve
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
Open
(With valve cap)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Service Port
Closed
(With cap)
Open
(Connected manifold
gauge w/charging
cylinder)
Closed
(With cap)
Closed
(With cap)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Closed
(With cap)
Open
(Connected manifold
gauge)
3-way Valve (Liquid Side)
3-way Valve (Gas Side)
Service Port
Closed
(With cap)
Open
(Push-pin)
Closed
(With cap)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Works
Shipping
Air purging
Installation and
Re-installation
Operation
Pumping down
(Transferring)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
Valve cap
To
piping
connection
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
Open
(With valve cap)
Closed
(Clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Flare nut
Hexagonal wrench(4 mm)
Open position
Closed position
Pin
Service
port cap
To outdoor unit
Service port
To
piping
connection
Flare nut
Open position
Closed position
Pin
Service port
To outdoor unit
Service
port cap
Untitled-19