CS-MC90KH, CU-MC140KH, CS-MC90KH, CU-MC180KH, CS-MC90KH, CU-3MC200KH - Panasonic Air Conditioner Service Manual (repair manual). Page 25

Read Panasonic CS-MC90KH / CU-MC140KH / CS-MC90KH / CU-MC180KH / CS-MC90KH / CU-3MC200KH Service Manual online

– 24  –
ORDER NO. MAC9807010C3
CS-MC90KH
Operation Details
3)  Air Circulation Mode Operation
• When the temperature near the ceiling reaches the setting temperature, Air Circulation Mode operation commences
at low airflow volume. It stops when the temperature drops to 2
°
C below the setting temperature.
Air Circulation Mode Operation Time Diagram
ON
Setting
Temp.
OFF
Compressor
Indoor Fan
Outdoor Fan
Operation
Indication LED
2°C
Intake Air Temp.
a                b                 c                d                 e
Lo
Lo
Operation
Stop
Higher
+2
°
C
Standard
±
0
°
C
Lower
–2
°
C
Cooling
27
°
C
25
°
C
23
°
C
Soft Dry
24
°
C
22
°
C
20
°
C
Cooling Mode
Soft Dry Mode
Setting Temperature (Standard)
25
°
C
22
°
C
Cooling Mode
Soft Dry Mode
23
°
C
Intake air
temperature
4) Automatic Mode Operation
Standard for Determining Operation Mode
(a) Indoor fan operates at Lo fan speed for 20 seconds.
(b) After judging indoor air temperature, the operation mode is determined and operation continued at the mode
determined.
(c) After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation
includes Cooling mode operation.
(d) If Automatic Mode operation is started while the air conditioner is operating, operation will continue. If current
operation is in Cooling mode (including the operation which is a part of Soft Dry mode operation), it will be
maintained, for 20 seconds at Lo fan speed. Then, the selected operation mode will continue.
(e) Room temperature adjustment.
The following are added to the setting temperature specified as above.