CS-MA70KE, CS-MA90KE, CS-MA120KE, CU-MA180KE, CU-MA190KE, CU-MA240KE - Panasonic Air Conditioner Service Manual (repair manual). Page 47

Read Panasonic CS-MA70KE / CS-MA90KE / CS-MA120KE / CU-MA180KE / CU-MA190KE / CU-MA240KE Service Manual online

– 46 –
CS-MA90KE
MAC9509078C2
    30      32       34      36      38      40      42       44   
 OUTDOOR  AIR TEMPERATURE (
°
C)
[Condition]  Room temperature: 27/19
°
C
 Cooling operation: At High fan
 Piping length: 5 m
8
7
6
5
14
13
12
11
10
0.65
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
   
I:                                                       Q:
Current (A)                              
-
     Cooling Capacity (kW)                          
-
LP:                                                         O: Outlet
Gas Side Piping Pressure (MPa)      
Air Temperature (
°
C)      
       
-
O
Q
I
L.P
Technical Data
L
L
L
L
L
Operation characteristics
CS-MA120KE / CU-MA240KE
The capability value shown is the value for one unit. For a total for two unit, multiply by 2.
    -4       -2        0         2        4       6         8       10
       OUTDOOR AIR TEMPERATURE (
°
C)
[Condition]  Room temperature: 20
°
C
 Heating operation: At High fan
 Piping length: 5 m
7
6
5
4
44
42
40
38
36
34
1.8
1.7
1.6
1.5
1.4
1.3
5.0
4.5
4.0
3.5
3.0
220V
240V
I:                                                       Q:
Current (A)                              
-
     Heating Capacity (kW)                          
-
HP:                                                         O: Outlet
Gas Side Piping Pressure (MPa)      
Air Temperature (
°
C)      
       
-
O
Q
I
L.P
1                   5                        10                     15      
                      PIPING LENGTH (m)
[Condition]  Room temperature: 27/19
°
C
 Outdoor temperature: 35/24
°
C
 Cooling operation: At High fan
7
6
5
4
13
12
11
10
9
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I:                                                       Q:
Current (A)                              
-
     Cooling Capacity (kW)                           
-
LP:                                                         O: Outlet
Gas Side Piping Pressure (MPa)      
Air Temperature (
°
C)      
       
-
O
Q
I
L.P
Cooling Characteristic
Heating Characteristic
Piping Length Characteristic (Heating)
•  Piping Length Characteristic (Cooling)
1                   5                       10                     15       
                      PIPING LENGTH (m)
[Condition]  Room temperature: 20
°
C
 Outdoor temperature: 7/6
°
C
 Heating operation: At High fan
7
6
5
4
4.5
4.0
3.5
3.0
2.5
1.9
1.8
1.7
1.6
46
44
42
38
36
220V
240V
I:                                                       Q:
Current (A)                              
-
     Heating Capacity (kW)                          
-
HP:                                                         O: Outlet
Gas Side Piping Pressure (MPa)      
Air Temperature (
°
C)      
       
-
O
Q
I
L.P
Untitled-6
6/30/00, 8:19 AM
46
Page of 56
Display