CS-LE9NKD, CS-LE12NKD, CU-LE9NKD, CU-LE12NKD - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-LE9NKD / CS-LE12NKD / CU-LE9NKD / CU-LE12NKD Service Manual online

Hi 
m
3
/min (ft
3
/m) 
12.0 (424)  
13.3 (470)  
Q-Lo 
m
3
/min (ft
3
/m) 
6.8 (239) 
8.0 (283) 
Lo 
m
3
/min (ft
3
/m) 
7.9 (279) 
9.7 (344) 
Me 
m
3
/min (ft
3
/m) 
9.2 (326) 
11.1 (392) 
Indoor Airflow 
(HEATING) 
Hi 
m
3
/min (ft
3
/m) 
11.5 (406) 
12.6 (445) 
Hi  (Cooling) 
m
3
/min (ft
3
/m) 
32.9 (1162)  
36.8 (1300)  
Outdoor Airflow 
Hi  (Heating) 
m
3
/min (ft
3
/m) 
32.9 (1162) 
36.8 (1300) 
Control Device 
 
Capillary Tube 
Capillary Tube 
Refrigerant Oil 
cm
3
 
FV50S  (250) 
FV50S (320) 
Refrigeration 
Cycle 
Refrigerant Type  g (oz) 
R410A, 640 (22.6) 
R410A, 690 (24.4) 
Height(I/D / O/D) mm (inch) 
283 (11-15/32)  530 (20-55/64)  283 (11-5/32)  624 (24-37/64) 
Width (I/D / O/D) mm (inch) 
803 (31-5/8) 
720 (28-11/32) 
803 (31-5/8) 
780 (30-45/64) 
Dimension 
Depth (I/D / O/D) mm (inch) 
216 (8-1/2) 
275 (10-53/64) 
216 (8-1/2) 
289 (11-3/8) 
Weight 
Net (I/D / O/D) 
kg (lb) 
8.5 (19) 
20 (44) 
8.5 (19) 
24 (53) 
Pipe Diameter  
(Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5 (16.4) 
5 (16.4) 
Length range (min – max)  m (ft) 
3 (9.8) ~ 15 (49.2) 
3 (9.8) ~ 15 (49.2) 
I/D & O/D Height different  m (ft) 
5.0 (16.4) 
5.0 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
20  (0.2) 
20 (0.2) 
P
ip
in
g
 
Length for Additional Gas  m (ft) 
7.0 (23.0) 
7.0 (23.0) 
Inner diameter 
mm 
16 
16 
Drain Hose 
Length 
mm 
500 
500 
Fin Material 
 
Pre coated 
Pre coated 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
2 x 16 x 19 
2 x 16 x 19 
Indoor 
Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 336 x 25.4 
610 x 336 x 25.4 
Fin Material 
 
Pre coated 
Pre coated 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x FPI 
 
1 x 24 x 19 
1 x 28 x 18 
Outdoor 
Heat 
Exchanger 
Size (W x H x D) 
mm 
661 x 504 x 18.19                     
715 x 588 x 18.19 
Material 
 
PP-12X13H2 
PP-12X13H2 
Air Filter 
Type 
 
One-touch 
One-touch 
Power Supply 
 
Indoor 
Indoor 
Power Supply Cord 
10A 
10A 
Thermostat 
 
Protection Device 
 
 
COOLING 
HEATING 
COOLING 
HEATING 
TEMPERATURE (°C ) 
DB 
WB 
DB 
WB 
DB 
WB 
DB 
WB 
Maximum 
32 
23 
30 
32 
23 
30 
Indoor Operation Range 
Minimum 
16 
11 
16 
16 
11 
16 
Maximum 
43 
26 
24 
18 
43 
26 
24 
18 
Outdoor Operation Range 
Minimum 
16 
11 
-5 
-6 
16 
11 
-5 
-6 
 
1.  Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bu lb (66.2°F 
Wet Bulb) and outdoor air temperature of 35°C Dry B ulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bu lb). 
2.  Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor ai r 
temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C  Wet Bulb (42.8°F Wet Bulb). 
3.  Specifications are subjected to change without prior notice for further improvement. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 55
Display