CAUTION 
 
17. During installation, install the refrigerant piping properly before running the compressor. Operation of compressor 
without fixing refrigeration piping and valves at opened condition will cause suck-in of air,  abnormal high pressure in 
refrigeration cycle and result in explosion, injury etc. 
 
18. During pump down operation, stop the compressor before remove the refrigeration piping.  Removal of refrigeration 
piping while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in 
refrigeration cycle and result in explosion, injury etc. 
 
19. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long 
period, the flare may break and cause refrigerant gas leakage. 
 
20. After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the 
refrigerant contacts with fire. 
 
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with 
fire. 
 
22. Recommended installation height for indoor unit shall be at least 2.5 m. 
 
23. The appliance shall be installed in accordance with national wiring regulations. 
 
24. Indoor unit must be installed close against the wall. 
 
24. All-pole disconnection incorporated in the fixed wiring is to be provided. 
 
25. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning 
rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown. 
 
 
 
 
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at 
surrounding of the unit, it may cause fire. 
 
2. Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts. 
Take care of the liquid refrigerant, it may cause frostbite. 
 
3. Do not install this appliance in a laundry room or other location where water may drip from the celling, etc. 
 
4. Thermal fuse specification for indoor unit: 250V 3.15A T3.15AL; outdoor unit: 250V 3.15A T3.15AL. 
 
5. Do not touch outdoor unit air inlet and aluminums fin. It may cause injury. 
 
 
6. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room 
and damage the furniture. 
 
7. Select an installation location which is easy for maintenance. 
 
8. Power supply connection to the air conditioner. 
Connect the power supply cord of the air conditioner to the mains using one of the following methods. 
Power supply point should be in easily accessible place for power disconnection in case of emergency. 
In some countries, permanent connection of this air conditioner to the power supply is prohibited. 
1) Power supply connection to the receptacle using a power plug. 
Use an approved 15/16A power plug with earth pin for the connection to the receptacle. 
2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for 
the permanent connection. It must be a double pole switch with a minimum 3.5 mm contact gap. 
 
9. Service and Installation work. 
It may need two people to carry out the installation work. 
 