Dimensions
Height
inch (mm)
10 - 31/32 (279)
21 - 9/32 (540)
Width
inch (mm)
31 - 15/32 (799)
27 - 17/32 (699)
Depth
inch (mm)
7 - 27/32 (199)
11 - 7/32 (285)
Net Weight
lb (kg)
20 (9.0)
86 (39)
Compressor
Type
Rotary (2 cylinders)
rolling piston type
Motor
Type
Induction (4-poles)
Rated
Output
W
500
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 30%
P.P + (Mica + Glass Fiber) 30%
Motor
Type
Transistor (4-poles)
Induction (6-poles)
Input
W
64
Rate Output
W
20
20
Fan Speed
Lo (Cool/Heat)
rpm
980 / 1,010
Me (Cool/Heat)
rpm
1,160 / 1,220
Hi (Cool/Heat)
rpm
1,280 / 1,380
760
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 14
1 / 20
FPI
21
19
Size (W × H × L)
mm
614 × 294 × 25.4
782.9 × 508 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(350)
Refrigerant (R-22)
g (oz)
780 (27.5)
Thermostat
Electronic Control
Protection Device
Electronic Control
Electronic Control
Length
mm
C1, C2 ; 1033, C3 ; 400
Capillary Tube
Flow Rate
l/min
C1, C2 ; 4.8, C3 ; 23.6
Inner Diameter
mm
C1, C2 ; 1.2, C3 ; 1.8
Air Filter
Material
Style
P.P.
Honeycomb
Fan Motor Capacitor
µF, VAC
2.0 µF, 400 VAC
  • 
Specifications are subject to change without notice for further improvement.