CS-G95KE, CS-G125KE, CU-G95KE, CU-G125KE - Panasonic Air Conditioner Service Manual (repair manual). Page 11

Read Panasonic CS-G95KE / CS-G125KE / CU-G95KE / CU-G125KE Service Manual online

Dimensions
Height
inch (mm)
10 - 31/32 (279)
21 - 9/32 (540)
Width
inch (mm)
31 - 15/32 (799)
27 - 17/32 (699)
Depth
inch (mm)
7 - 27/32 (199)
11 - 7/32 (285)
Net Weight
lb (kg)
20 (9.0)
95 (43.0)
Compressor
Type
Rotary (2 cylinders)
rolling piston type
Motor
Type
Induction (4-poles)
Rated
Output
W
500
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 30%
P.P + (Mica + Glass Fiber) 30%
Motor
Type
Transistor (4-poles)
Induction (6-poles)
Input
W
67
Rate Output
W
20
25
Fan Speed
Lo (Cool/Heat)
rpm
1,170 / 1,200
Me (Cool/Heat)
rpm
1,320 / 1,360
Hi (Cool/Heat)
rpm
1,410 / 1,480
790
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row / Stage
(Plate fin configuration, forced draft)
2 / 14
2 / 20
FPI
21
16
Size (W × H × L)
mm
614 × 294 × 25.4
693.5 × 508 × 44
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(350)
Refrigerant (R-22)
g (oz)
1,070 (37.8)
Thermostat
Electronic Control
Protection Device
Electronic Control
Electronic Control
Length
mm
C1, C2 ; 720, C3 ; 420
Capillary Tube
Flow Rate
l/min
C1, C2 ; 7.2, C3 ; 14.4
Inner Diameter
mm
C1, C2 ; 1.3, C3 ; 1.5
Air Filter
Material
Style
P.P.
Honeycomb
Fan Motor Capacitor
µF, VAC
2.0 µF, 400 VAC
  • 
Specifications are subject to change without notice for further improvement.
11
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Page of 113
Display

Click on the first or last page to see other CS-G95KE / CS-G125KE / CU-G95KE / CU-G125KE service manuals if exist.