2.1. Hide-away type
2.1.1. Thin, lightweight design
• The unit has a low height, so it allows installation in limited
ceiling spaces. The lightweight, attractive design simplifies
installation, and matches virtually all room interiors.
installation, and matches virtually all room interiors.
2.1.2. Flexible installation
• The powerful airflow enables a longer duct to be used.
Since the air outlet can be installed away from the main
unit, a variety of air conditioner layouts become possible.
unit, a variety of air conditioner layouts become possible.
2.1.3. Easy maintenance
• Maintenance works can be done from the underside of the
indoor unit.
2.2. Outdoor unit
2.2.1. Flexible installation in smaller
spaces
• Space-saving outdoor unit with the improvement of the
outdoor unit fan makes it possible to install the outdoor unit
into a smaller space where the conventional model cannot
be installed.
into a smaller space where the conventional model cannot
be installed.
• Long pipe design with a maximum piping length of 50m.
• Additional charging of refrigerant are not required for 30m
• Additional charging of refrigerant are not required for 30m
of pipe length.
• Flexible 4-way piping.
• Centralized drain method gather multiple outdoor units’
drain pipes into a single drain pipe to make installation
easier and also improve appearance.
easier and also improve appearance.
• Side-by-side continuous installation is possible even for
outdoor units with different capacities.
2.2.2. Quiet, efficient design
• A host of silencing technologies achieves super-quiet
operation.
• The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape
suppresses the generation of vortexes, thus reduces air
flows noise.
suppresses the generation of vortexes, thus reduces air
flows noise.
• Operating efficiency is improved and energy consumption is
reduced.
2.2.3. Low ambient cooling operation
• The unit can set for cooling even when the outdoor
temperature drops to -5°C for regular cooling condition.
• However, cooling operation at -15°C is possible in non-
residential computer rooms, etc., where the temperature is
not less than 21°C and humidity is not more than 45%.
not less than 21°C and humidity is not more than 45%.
2 FEATURES
4