3.1. Product Specification
3 Specification
3.1.1. CS-F18DTE5 CU-L34DBE5
ITEM / MODEL
Indoor Unit
Outdoor Unit
Main Body
CS-F18DTE5 x 2
CU-L34DBE5
Remote
CZ-RD513C (Wired)
Control
CZ-RL513T (Wireless)
Cooling Capacity
kW
10.0
BTU/h
34,100
Heating Capacity
kW
11.2
BTU/h
38,200
Refrigerant Charge-less
m
30
Standard Air Volume for High,
m
3
/min
Hi 14.0 x 2 Me 12.1 x 2 Lo 11.1 x 2
Hi 98
Medium and Low Speed
cfm
494 x 2
426 x 2
392 x 2
3460
Outside Dimension (H x W x D)
mm
210 x 1245 x 700
1340 x 900 x 320
inch
8-9/32 x 49-1/64 x 27-9/16
52-7/8 x 35-7/16 x 12-19/32
Net Weight
kg (lbs)
33 (73)
110 (242)
Piping
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 12.7 (1/2) Flared Type
O.D Ø 15.88 (5/8) Flared Type
Liquid
mm (inch)
O.D Ø 6.35 (1/4) Flared Type
O.D Ø 9.53 (3/8) Flared Type
Drain
mm
O.D Ø 20
I.D Ø 20 x 1
Compressor
Type, Number of Set
-
Hermetic - 2P (Rotary), 1
Starting Method
-
DC-INV control
Motor
Type
-
4-pole single phase brushless motor
Rated Output
kW
-
2.6
Fan
Type, Number of Set
Sirocco fan-4
Mix flow fan - 2
Motor
Type
4-pole single phase induction motor
6-pole single phase induction motor
Rated Output
kW
0.08 x 2
0.07 x 2
Air-heat Exchanger (Row x Stage x FPI)
Slit-fin type (2 x 12 x 18)
Corrugate-fin type (2 x 51 x 18)
Refrigerant Control
-
Exp. Valve
Refrigerant Oil (Charged)
cm
3
-
FV50S (1200)
Refrigerant (Charged) R410A
kg (oz)
-
3.30 (116)
Running
Adjustment
Control Switch
Wireless or Wired Remote Control
-
Room Temperature
Thermostat
-
Safety Devices
Temperature, current and pressure protection control for compressor,
Internal thermostat for FM, High pressure switch,
Current trans, Crankcase heater
Noise Level
dB (A)
Hi 41 Lo 37
Cooling 52, Heating 54
Power level dB
Cooling : Hi 58 Lo 54
Heating : Hi 58 Lo 54
Cooling 66, Heating 68
Moisture Removal
L/h
6.0
EER
W/W
3.33
COP
W/W
3.41
 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
 2. Heating capacities are based on indoor temperature 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50 Hz)
ITEM / MODEL
Condition by JIS-B8615
Volts
V
220
230
240
Phase
Single
Single
Single
Power Consumption
kW
Cool
3.00
3.00
3.00
Heat
3.28
3.28
3.28
Running Current
A
Cool
14.0
13.6
13.1
Heat
15.4
14.9
14.4
Starting Current
A
14.0
13.6
13.1
Power Factor
%
Cool
97
96
95
Heat
97
96
95
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Power source
AC, 1~220V, 230V, 240V 50Hz