CS-F18DTE5, CU-L34DBE5 - Panasonic Air Conditioner Service Manual (repair manual)

cs-f18dte5, cu-l34dbe5 service manual
Model
CS-F18DTE5 CU-L34DBE5
Pages
127
Size
16.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR CONDITIONER
File
cs-f18dte5-cu-l34dbe5.pdf
Date

Read Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual online

 1 
Service Information 
3
 1.1. 
Example of trouble at test operation 
3
 1.2. 
Caution of test operation 
3
 1.3. 
Caution during automatic address setting 
3
 1.4. 
Operation range 
4
 2 
Features 
5
 2.1. 
Ceiling type 
5
 2.2. 
Outdoor unit 
5
 2.3. 
A brand-new control method 
6
CS-F18DTE5 CU-L34DBE5
 2.4. 
Wired Remote Control 
7
 2.5. 
Wireless Remote Control 
7
 2.6. 
Group Control Equipment 
8
 3 
Specification 
9
 3.1. 
Product Specification 
9
 4 
Dimensions 
10
 4.1. 
CS-F18DTE5 
10
 4.2. 
CU-L34DBE5 
11
Air Conditioner
CONTENTS
 Page 
Page
Order No. MAC0503046C2
 5 
Refrigeration Cycle 
12
 6 
Block Diagram 
13
 6.1. 
CS-F18DTE5 
13
 6.2. 
CU-L34DBE5 
14
 7 
Wiring Diagram 
15
 7.1. 
CS-F18DTE5 
15
 7.2. 
CU-L34DBE5 
16
 8 
Remote Control Operating Instructions 
17
 8.1. 
Wired Remote Control 
17
 8.2. 
Wireless Remote Control 
18
 9 
Operation Control 
19
 9.1. 
Operation mode 
19
 9.2. 
Compressor start control 
19
 9.3. 
Cooling operation 
19
 9.4. 
Heating mode operation 
21
 9.5. 
Louver control 
24
 9.6. 
Odour removing operation 
25
 9.7. 
Energy save operation 
26
 9.8. 
Outdoor fan remaining heat removal control 
26
 9.9. 
Crank case heater control 
26
 9.10. Valve error 
26
 9.11. Pump down operation 
27
 10 Installation Instruction 
28
 10.1. Pipe length 
28
 10.2. Refrigerant additional charge 
30
 10.3. Position of the centre gravity 
30
 10.4. Indoor unit installation 
31
 10.5. Outdoor unit installation  
40
 10.6. Wired remote control installation 
51
 10.7. Wireless remote control installation manual 
58
 10.8. Twin systems installation 
65
 11 Installation and Servicing Air Conditioner Using R410A 
66
 11.1. Outline 
66
 11.2. Tools for installing/servicing refrigerant piping 
67
 11.3. Refrigerant piping work 
71
 11.4. Installation, transferring, servicing 
73
 12 Troubleshooting Guide 
77
 12.1. For standard installation 
77
 12.2. During twin operation 
79
 12.3. During group control operation 
81
 12.4. Address setting for twin system 
82
 12.5. Address setting for group control system 
83
 12.6. Wiring mistake prevention 
85
 12.7. Test operation and self diagnosis 
86
 12.8. Emergency operation 
90
 12.9. Self-diagnosis 
91
 13 Technical Data 
93
 13.1. Sound data 
93
 13.2. Sound measurement point 
94
 13.3. Reaching distance 
95
 13.4. Discharge and suction pressure 
96
 13.5. Capacity and power consumption 
97
 13.6. Fan performance 
104
 13.7. Safety device 
105
 13.8. Operating characteristics 
105
 14 Replacement Parts 
106
 14.1. Indoor unit 
106
 14.2. Outdoor unit 
111
 15 Electronic Circuit Diagram 
115
 15.1. Indoor unit 
115
 15.2. Outdoor unit 
119
 15.3. Wired remote control 
126
 15.4. Wireless remote control 
127
 15.5. Print pattern 
128
2
CS-F18DTE5 CU-L34DBE5 /
1 Service Information
Notice of Address setting for NEW Ceiling / NEW Outdoor Unit.
The new Ceiling / New Outdoor models are possible to have address setting for twin control by automatic when main
power supply is switched on.
(Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However, this address setting is only
possible when made proper wiring connection and also Indoor unit should be original virgin unit
.
1.1. Example of trouble at test operation
If found out as following phenomenon at test operation on site, it may have possibility of wrong address setting.
Therefore, please ensure of the address setting.
 1. LCD display of wired remote control had not illuminate although the main power supply switch is ‘on’.
 2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoor unit cannot be operated.
(But, it is necessary to take 3 to 5 minutes for outdoor unit to start from the timing of remote control ON/OFF switch is ‘on’.)
 3. P.C. board had memorized wrong setting information.
 a. If main power supply is switched ‘on’ with the wrong connection.
 b. When changing the connection or combination of units due to re-installation etc.
 • When changing the system from twin control to normal one to one system.
 • When making the replacement of units as master and slave etc.
1.2. Caution of test operation
Do not touch the remote control switch and do not change any wirings for one minute when the main power supply switch is ‘on’.
(Because the unit is having automatic address setting during the first one minute.)
1.3. Caution during automatic address setting
When main power supply switch is ‘on’, the P.C. board will automatically memorized the connecting system.
Consequently, when initial power supply is ‘on’, there will not be interchangeability of units even of the same type and same
capacity unit. Therefore unable to connect the unit to another system.
3
CS-F18DTE5 CU-L34DBE5 /
1.4. Operation range
1.4.1. Power Supply
The applicable voltage range for each unit is given in the following table. The working voltage among the three phases must be
balanced within a 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher than 85% of
the rated voltage.
MODEL
Unit Main Power
Applicable Voltage
CU-
Phase, Volts
Hz
Max
Min
L34DBE5
1~240
50
264
216
1~220
50
242
198
1~230
50
253
207
1.4.2. Indoor and Outdoor Temperature
 • Model 50Hz CU-L34DBE5
Operating
Hz
Indoor Temp. (D.B./W.B.) (°C)
Outdoor Temp. (D.B./W.B.) (°C)
Max
Min
Max
Min
Cooling
50
32/23
21/15
43/-
-15/-
Heating
50
27/-
16/-
24/18
-20/-
4
CS-F18DTE5 CU-L34DBE5 /
Page of 127
Display

Download Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-F18DTE5 / CU-L34DBE5 Service Manual in PDF. CS-F18DTE5 / CU-L34DBE5 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-F18DTE5 / CU-L34DBE5 Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.