Read Panasonic CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE Service Manual online
86
13.2. Sensible Capacity Chart
O CS-E9GFEW CU-E9GFE
O CS-E12GFEW CU-E12GFE
O CS-E18GFEW CU-E18GFE
230V
Outdoor Temp. (
°C)
30
°C
35
°C
40
°C
46
°C
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
D.B.
W.B.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
27
17.0
2.48
2.13
0.52
2.32
2.05
0.56
2.16
1.97
0.60
1.96
1.88
0.65
19.0
2.50
0.57
19.5
2.72
2.23
0.53
2.55
2.15
0.57
2.37
2.06
0.61
2.15
1.97
0.66
22.0
2.96
2.31
0.54
2.77
2.22
0.58
2.58
2.13
0.62
2.34
2.03
0.67
230V
Outdoor Temp. (
°C)
30
°C
35
°C
40
°C
46
°C
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
D.B.
W.B.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
27
17.0
3.47
2.49
0.89
3.25
2.40
0.96
3.02
2.30
1.03
2.74
2.20
1.11
19.0
3.50
0.97
19.5
3.81
2.61
0.90
3.57
2.51
0.97
3.32
2.41
1.04
3.02
2.30
1.12
22.0
4.15
2.70
0.92
3.88
2.60
0.98
3.61
2.49
1.06
3.28
2.38
1.14
230V
Outdoor Temp. (
°C)
30
°C
35
°C
40
°C
46
°C
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
D.B.
W.B.
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
27
17.0
4.96
3.26
1.44
4.64
3.14
1.54
4.32
3.01
1.65
3.92
2.87
1.78
19.0
5.00
1.56
19.5
5.45
3.41
1.45
5.10
3.28
1.56
4.74
3.15
1.67
4.31
3.01
1.80
22.0
5.92
3.53
1.47
5.55
3.40
1.58
5.16
3.26
1.70
4.69
3.11
1.83
TC
SHC
IP
SHC
IP
-
-
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27
°C/19°C
Outdoor 35
°C/24°C
Click on the first or last page to see other CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE service manuals if exist.