Order No. RAC0704001C2
Air Conditioner
CS-E9GFEW  CU-E9GFE
CS-E12GFEW  CU-E12GFE
CS-E18GFEW  CU-E18GFE
TABLE OF CONTENTS
PAGE
PAGE
1 Safety Precautions----------------------------------------------- 2
2 Specifications 
----------------------------------------------------- 4
2.1. Floor Type --------------------------------------------------- 4
2.2. Outdoor Unit: CU-2E15GBE ---------------------------10
2.3. Outdoor Unit: 3E18EBE--------------------------------- 11
2.4. Outdoor Unit: CU-3E23CBPG  CU-
4E27CBPG-------------------------------------------------12
3 Features ------------------------------------------------------------16
3.1. Remote Control -------------------------------------------17
3.2. Indoor Unit--------------------------------------------------18
3.3. Outdoor Unit----------------------------------------------- 19
4 Location of Controls and Components------------------ 20
4.1. Indoor Unit ------------------------------------------------- 20
4.2. Outdoor Unit----------------------------------------------- 20
4.3. Remote Control------------------------------------------- 20
5 Dimensions ------------------------------------------------------- 21
5.1. Indoor Unit ------------------------------------------------- 21
5.2. Outdoor Unit----------------------------------------------- 22
6 Refrigeration Cycle Diagram -------------------------------- 24
Please file and use this manual together with the Service Manual for Model No. CU-2E15GBE, Order No. MAC0704001A2, Model
No. CU-3E18EBE, Order No. RAC0602011C2, Model No. CU-3E23CBPG, CU-4E27CBPG, Order No.RAC0209005C2.
2
6.1. CS-E9GFEW  CU-E9GFECS-E12GFEW  CU-
E12GFE ---------------------------------------------------- 24
6.2. CS-E18GFEW  CU-E18GFE -------------------------- 25
7 Wiring Connection Diagram --------------------------------- 26
7.1. Indoor Unit ------------------------------------------------- 26
7.2. Outdoor Unit ----------------------------------------------- 27
8 Electronic Circuit Diagram----------------------------------- 29
8.1. Indoor Unit / Remote Controller ---------------------- 29
8.2. Outdoor Unit ----------------------------------------------- 31
9 Operation and Control----------------------------------------- 34
9.1. Simultaneous Operation Control (Multi Type
Only)--------------------------------------------------------- 34
9.2. Basic Function -------------------------------------------- 35
9.3. Room Temperature Control (Compressor
Control) ----------------------------------------------------- 36
9.4. Automatic Operation------------------------------------- 37
9.5. Indoor Fan Motor Operation --------------------------- 39
9.6. Airflow Direction Control-------------------------------- 41
9.7. Powerful Mode Operation ------------------------------ 44
9.8. ON Timer Control ---------------------------------------- 44
9.9. OFF Timer Control --------------------------------------- 44
9.10. Auto Restart Control------------------------------------- 45
9.11. Indication Panel------------------------------------------- 45
9.12. Auto Operation Switch --------------------------------- 45
9.13. Freeze Prevention Control ---------------------------- 45
9.14. Dew Prevention Control-------------------------------- 46
9.15. Protection Control Features--------------------------- 46
10 Self Diagnosis Display---------------------------------------- 53
10.1. Self Diagnosis Function -------------------------------- 53
10.2. Error Codes Table --------------------------------------- 54
11 Installation Instruction---------------------------------------- 56
11.1. Auto switch operation----------------------------------- 56
11.2. Changing the remote control transmission
code --------------------------------------------------------- 56
11.3. Indoor Unit------------------------------------------------- 57
11.4. Outdoor Unit ---------------------------------------------- 65
12 Disassembly and Assembly Instructions -------------- 68
12.1. Indoor Unit------------------------------------------------- 68
12.2. Outdoor Unit ---------------------------------------------- 72
13 Technical Data --------------------------------------------------- 74
13.1. Operation Characteristics ----------------------------- 74
13.2. Sensible Capacity Chart ------------------------------- 86
14 Exploded View and Replacement Parts List----------- 87
14.1. Indoor Unit------------------------------------------------- 87
14.2. CU-E9GFE  CU-E12GFE------------------------------ 90
14.3. CU-E18GFE----------------------------------------------- 92
1 Safety Precautions
• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.
• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and
main circuit for the model installed.
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below.
Incorrect installation or servicing due to ignoring of the instruction will cause harm or damage, and the seriousness is classified
by the following indications.
The items to be followed are classified by the symbols:
• Carry out test running to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties.
This symbol denotes item that is PROHIBITED from doing.
1.
Engage dealer or specialist for installation and servicing. If installation or servicing done by the user is defective, it will cause water leakage,
electrical shock or fire.
2.
Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
3.
Use the attached accessories parts and specified parts for installation and servicing. Otherwise, it will cause the set to fall, water leakage,
fire or electrical shock. 
4.
Install at a strong and firm location which is able to withstand the set's weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury. 
3
5.
For electrical work, follow the local national wiring standard, regulation and the installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
6.
Use the specified cable and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause
heat-up at connection point of terminal, fire or electrical shock.
8.
When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration
cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in
explosion and injury.
9.
Thickness of copper pipes used must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.
10. It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other
electrical appliances. Otherwise, it will cause fire or electrical shock.
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding
of the unit, it may cause fire. 
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture. 
4.
Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high
temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F/600°C).
1.
Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a
location for easy maintenance.
2.
Power supply connection to the conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
methods. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. 
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the
socket.
2. Power supply connection to a circuit breaker for the permanent connection. Use an approved circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3.5 mm contact gap.
3.
Do not release refrigerant during piping work for installation, servicing reinstallation and during repairing a refrigeration parts. Take care of
the liquid refrigerant, it may cause frostbite.
4.
Installation work. It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
4
2 Specifications
2.1.
Floor Type
2.1.1.
CS-E9GFEW  CU-E9GFE
ITEM
UNIT
CS-E9GFEW
CU-E9GFE
Cooling Capacity
kW
2.50 (0.80 ~ 3.00)
kCal/h
2,150 (690 ~ 2,580)
BTU/h
8,500 (2,700 ~ 10,200)
Heating Capacity
kW
3.60 (0.80 ~ 5.00)
kCal/h
3,100 (690 ~ 4,300)
BTU/h
12,300 (2,700 ~ 17,100)
Moisture Removal
l/h
1.4
pt/h
(2.9)
Power Source
Phase
Single
V
220 / 230 / 240
Cycle
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 5.6 (198)
Heating; 5.6 (198)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 7.4 (261)
Heating; 7.6 (268)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 9.3 (328)
Cooling; 29.8 (1,050)
Heating; 9.6 (339)
Heating; 29.8 (1,050)
Noise Level
dB (A)
Cooling; High 38, Low 27
Cooling; 46
Heating; High 38, Low 28
Heating; 47
Power Level dB
Cooling; High 54
Cooling; 59
Heating; High 54
Heating; 60
Electrical Data
Input
W
Cooling; 570 (175 - 780)
Heating; 865 (165 - 1,360)
Running Current
A
Cooling; 2.75 / 2.70 / 2.65
Heating; 4.20 / 4.05 / 3.90
EER
W/W(kcal/hw), BTU/hw
Cooling; 4.39 (3.78), 15.0
COP
W/W(kcal/hw), BTU/hw
Heating; 4.16 (3.58), 14.2
Starting Current
A
4.20
Piping Connection Port                                           
(Flare piping)
inch
G; Half Union 3/8"
G; 3-way valve 3/8"
inch
L; Half Union 1/4"
L; 2-way valve 1/4"
Piping Size                                                      
(Flare piping)
inch
G; (gas side); 3/8"
G; (gas side); 3/8"
inch
L; (liquid side); 1/4"
L; (liquid side); 1/4"
Drain Hose
Inner diameter
mm
15
Length
mm
220
Power Cord Length
Number of core-wire
Dimensions
Height
(inch) mm
23-5/8 (600)
21-1/4 (540)
Width
(inch) mm
27-9/16 (700)
30-23/32 (780)
Depth
(inch) mm
8-9/32 (210)
11-3/8 (289)
Net Weight
Ib (kg)
31 (14)
82 (37)
Page of 94
Display

Download Panasonic CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE Service Manual in PDF. CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.