CS-E9GFEW, CU-E9GFE, CS-E12GFEW, CU-E12GFE, CS-E18GFEW, CU-E18GFE - Panasonic Air Conditioner Service Manual (repair manual). Page 4

Read Panasonic CS-E9GFEW / CU-E9GFE / CS-E12GFEW / CU-E12GFE / CS-E18GFEW / CU-E18GFE Service Manual online

4
2 Specifications
2.1.
Floor Type
2.1.1.
CS-E9GFEW  CU-E9GFE
ITEM
UNIT
CS-E9GFEW
CU-E9GFE
Cooling Capacity
kW
2.50 (0.80 ~ 3.00)
kCal/h
2,150 (690 ~ 2,580)
BTU/h
8,500 (2,700 ~ 10,200)
Heating Capacity
kW
3.60 (0.80 ~ 5.00)
kCal/h
3,100 (690 ~ 4,300)
BTU/h
12,300 (2,700 ~ 17,100)
Moisture Removal
l/h
1.4
pt/h
(2.9)
Power Source
Phase
Single
V
220 / 230 / 240
Cycle
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
Cooling; 5.6 (198)
Heating; 5.6 (198)
Indoor Air (Me)
m
3
/min (cfm)
Cooling; 7.4 (261)
Heating; 7.6 (268)
Indoor Air (Hi)
m
3
/min (cfm)
Cooling; 9.3 (328)
Cooling; 29.8 (1,050)
Heating; 9.6 (339)
Heating; 29.8 (1,050)
Noise Level
dB (A)
Cooling; High 38, Low 27
Cooling; 46
Heating; High 38, Low 28
Heating; 47
Power Level dB
Cooling; High 54
Cooling; 59
Heating; High 54
Heating; 60
Electrical Data
Input
W
Cooling; 570 (175 - 780)
Heating; 865 (165 - 1,360)
Running Current
A
Cooling; 2.75 / 2.70 / 2.65
Heating; 4.20 / 4.05 / 3.90
EER
W/W(kcal/hw), BTU/hw
Cooling; 4.39 (3.78), 15.0
COP
W/W(kcal/hw), BTU/hw
Heating; 4.16 (3.58), 14.2
Starting Current
A
4.20
Piping Connection Port                                           
(Flare piping)
inch
G; Half Union 3/8"
G; 3-way valve 3/8"
inch
L; Half Union 1/4"
L; 2-way valve 1/4"
Piping Size                                                      
(Flare piping)
inch
G; (gas side); 3/8"
G; (gas side); 3/8"
inch
L; (liquid side); 1/4"
L; (liquid side); 1/4"
Drain Hose
Inner diameter
mm
15
Length
mm
220
Power Cord Length
Number of core-wire
Dimensions
Height
(inch) mm
23-5/8 (600)
21-1/4 (540)
Width
(inch) mm
27-9/16 (700)
30-23/32 (780)
Depth
(inch) mm
8-9/32 (210)
11-3/8 (289)
Net Weight
Ib (kg)
31 (14)
82 (37)
Page of 94
Display