CS-E9DKDW, CU-E9DKD, CS-E12DKDW, CU-E12DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD Service Manual online

3 Product Specifications
3.1. CS-E9DKDW CU-E9DKD
Unit
CS-E9DKDW
CU-E9DKD
Cooling Capacity
kW
kcal/h
BTU/h
2.6 (0.80 - 3.00)
2,240 (690 - 2,580)
8,870 (2,050 - 10,200)
Heating Capacity
kW
kcal/h
BTU/h
3.6 (0.80 - 5.00)
3,100 (690 - 4,300)
12,300 (2,050 - 17,100)
Moisture Removal
l/h
Pint/h
1.6
(3.4)
Power Source (Phase, Voltage, Cycle)
ø
V
Hz
Single
220 - 230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 6.2 (220)
Heating; 6.6 (230)
Me
m
3
/min (cfm)
Cooling; 7.9 (280)
Heating; 8.6 (300)
Hi
m
3
/min (cfm)
Cooling; 9.6 (340)
Cooling; 29.8 (1,050)
Heating; 10.5 (370)
SHi
m
3
/min (cfm)
Cooling; 9.9 (350)
Heating; 10.8 (380)
dB (A)
Cooling; High 39, Low 26
Cooling; 46
Heating; High 40, Low 27
Heating; 47
Noise Level
Power level dB
Cooling; High 50
Cooling; High 59
Heating; High 51
Heating; High 60
Electrical Data
Input
W
Cooling; 600 (175 - 780)
Heating; 845 (165 - 1,360)
Running Current
A
Cooling; 3.0 - 2.9
Heating; 4.2 - 4.0
EER
W/W (kcal/hw), BTU/hw
Cooling; 4.33 (3.73), 14.8
COP
W/W (kcal/hw), BTU/hw
Heating; 4.26 (3.67), 14.6
Starting Current
A
4.2
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
G (gas side) ; 3/8”
L (liquid side) ; 1/4”
Drain
Hose
Inner diameter
mm
12
Length
m
0.65
7
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
Page of 98
Display

Click on the first or last page to see other CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD service manuals if exist.