CS-E9DKDW, CU-E9DKD, CS-E12DKDW, CU-E12DKD - Panasonic Air Conditioner Service Manual (repair manual)

cs-e9dkdw, cu-e9dkd, cs-e12dkdw, cu-e12dkd service manual
Model
CS-E9DKDW CU-E9DKD CS-E12DKDW CU-E12DKD
Pages
98
Size
15.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
cs-e9dkdw-cu-e9dkd-cs-e12dkdw-cu-e12dkd.pdf
Date

Read Panasonic CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD Service Manual online

 1 
Features 
2
 2 
Functions 
3
 2.1. 
Remote Control 
3
 2.2. 
Indoor Unit 
4
 2.3. 
Outdoor Unit 
6
 3 
Product Specifications 
7
 3.1. 
CS-E9DKDW CU-E9DKD 
7
 3.2. 
CS-E12DKDW CU-E12DKD 
9
 4 
Dimensions 
11
 4.1. 
Indoor Unit & Remote Control 
11
 4.2. 
Outdoor Unit 
12
 5 
Refrigeration Cycle Diagram 
13
 6 
Block Diagram 
14
 7 
Wiring Diagram 
15
 8 
Operation Details 
16
 8.1. 
Basic Function 
16
CS-E9DKDW CU-E9DKD
CS-E12DKDW CU-E12DKD
 8.2. 
Protection Control Features 
35
 9 
Operating Instructions 
44
 10 Installation Instructions 
50
 10.1. Safety Precautions 
50
 10.2. Indoor Unit 
53
 10.3. Outdoor Unit 
57
 11 Installation And Servicing Air Conditioner Using R410A 
61
 11.1. Outline 
61
 11.2. Tools For Installing/Servicing Refrigerant Piping 
62
 11.3. Refrigerant Piping Work 
66
 11.4. Installation, Transferring, Servicing 
68
 12 Servicing Information 
72
 12.1. Troubleshooting 
72
 12.2. Breakdown Self Diagnosis Function 
74
 12.3. Remote Control 
76
Air Conditioner
CONTENTS
 Page 
Page
Order No: MAC0412071C2
 12.4. Disassembly of Parts 
77
 13 Technical Data 
80
 13.1. Operation Characteristics 
80
 13.2. Sensible Capacity Chart 
82
 14 Exploded View (Indoor Unit) 
83
 14.1. CS-E9DKDW CS-E12DKDW 
83
 15 Replacement Parts List (Indoor Unit) 
84
 15.1. CS-E9DKDW CS-E12DKDW 
84
 16 Exploded View (Outdoor Unit) 
85
  • Product
  − Four modes of operation selection
  − Powerful Mode operation
  − Delay ON Timer and OFF Timer
  − Ionizer Mode Operation
  − Quiet Mode Operation
  − Automatic air swing and manual adjusted by Remote
Control for horizontal and vertical airflow.
  − Supersonic Air Purifying System with Super Alleru-
Buster.
Inactive various harmful airbone elements including
allergens, viruses and bacteria.
Generated supersonic waves enhance the ability to
collect dust and dirt in the air.
 16.1. CU-E9DKD CU-E12DKD 
85
 17 Replacement Parts List (Outdoor Unit) 
86
 17.1. CU-E9DKD CU-E12DKD 
86
 18 Electronic Circuit Diagram 
87
 18.1. Indoor Unit 
87
 18.2. Outdoor Unit 
91
 18.3. Remote Control 
96
 18.4. Print Pattern Indoor Unit Printed Circuit Board 
97
 18.5. Print Pattern Outdoor Unit Printed Circuit Board 
98
  • Serviceability Improvement
  − Removable and washable Front Panel
  − Breakdown Self Diagnosis function
  • Environmental Protection
  − Non-ozone depletion substances refrigerant (R410A)
  • Quality Improvement
  − Gas leakage detection
  − Deice operation
  − Auto restart control
1 Features
2
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
2 Functions
2.1. Remote Control
Operation OFF / ON
OFF/ON
I
Room Temperature Setting
TEMP
Operation Mode Selection
a
Automatic Operation
HEAT
Heating Operation
COOL
Cooling Operation
DRY
Soft Dry Operation
Time / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Quiet Mode Operation OFF / ON
QUIET
Airflow Direction Control
• 24-hour, OFF / ON Real Timer Setting.
Timer Operation Selection
Timer Operation Set / Cancel
• ON Timer and OFF Timer setting and
cancellation.
CLOCK
Powerful Mode Operation
POWERFUL
• Increase or decrease set temperature
(16°C to 30°C)
Vertical Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Horizontal Automatic Airflow
Direction Control and Manual
Airflow Direction Control (5
stages of adjustment).
Indoor Fan Speed Selection
FAN SPEED
Low
Medium-
Medium
Medium+
High
AUTO
Automatic Fan Speed
FAN
Check Point
Reset Point
RESET
TIMER
SET
CANCEL
CHECK
MODE
AIR SWING
• Breakdown self diagnosis function.
• Clear memory data.
Ion Mode Operation OFF / ON
ON
OFF
3
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
2.2. Indoor Unit
Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to
run Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (A
↔B Mode).
• Press continuously for 16s or < 21s  to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
Quiet Mode
Four Operation Modes
• Automatic, Heating, Cooling and Soft Dry
Operation.
Delay ON Timer and OFF Timer
Powerful Mode
• For quick cooling or heating.
POWER
(Green) ........ Lights up in
operation, blinks in
Automatic Operation
Mode judging and
Hot Start operation.
TIMER
(Orange) ...... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
QUIET
(Orange) ...... Lights up in Quiet
Mode Operation.
POWERFUL
 (Orange) ..... Lights up when
Powerful Mode is
selected.
 (Green) .............. Lights up in Ionizer
Mode Operation.
SUPER
ALLERU-BUSTER
 (Blue) ... Lights up in
operation.
Automatic and 5 Manual Indoor
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control
• To provide quiet operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
4
CS-E9DKDW CU-E9DKD / CS-E12DKDW CU-E12DKD
Page of 98
Display

Download Panasonic CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD Service Manual (Repair Manual)

Here you can read online and download Panasonic CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD Service Manual in PDF. CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic CS-E9DKDW / CU-E9DKD / CS-E12DKDW / CU-E12DKD Air Conditioner. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.