Read Panasonic CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD Service Manual online
116
17.4.23 F93 (Compressor Rotation Failure)
Malfunction Decision Conditions
A compressor rotation failure is detected by checking the compressor running condition through the position
detection circuit.
Malfunction Caused
Compressor terminal disconnect
Faulty Outdoor PCB
Faulty
compressor
Troubleshooting
Click on the first or last page to see other CS-E7PKDW / CS-E9PKDW / CS-E12PKDW / CS-E15PKDW / CS-E18PKDW / CS-E24PKDW / CU-E7PKD / CU-E9PKD / CU-E12PKD / CU-E15PKD / CU-E18PKD / CU-E24PKD service manuals if exist.