Read Panasonic CS-E7NKDW / CS-E9NKDW / CS-E12NKDW / CS-E15NKDW / CS-E18NKDW / CU-E7NKD / CU-E9NKD / CU-E12NKD / CU-E15NKD / CU-E18NKD Service Manual online
13
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L)
mm
810 x 315 x 25.4
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 31 x 19
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
36.4 x 651 x 854.5:824.5
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
Dry Bulb
Wet Bulb
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
-
Indoor
Operation
Range
Heating
Minimum 16
-
Maximum 43
26
Cooling
Minimum 16
11
Maximum 24
18
Outdoor
Operation
Range
Heating
Minimum -5
-6
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
Click on the first or last page to see other CS-E7NKDW / CS-E9NKDW / CS-E12NKDW / CS-E15NKDW / CS-E18NKDW / CU-E7NKD / CU-E9NKD / CU-E12NKD / CU-E15NKD / CU-E18NKD service manuals if exist.