Read Panasonic CS-E7GKEW / CS-E7GKDW / CS-E9GKEW / CS-E9GKDW / CS-E12GKEW / CS-E12GKDW / CS-E15GKEW / CS-E15GKDW / CS-E18GKEW / CS-E18GKDW / CU-2E15GBE Service Manual Simplified online
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the products dealt with in this service information by anyone else could result in serious injury or death.
3E23CBPG, CU- 4E27CBPG, Order No. RAC0209005C2, Model No. CU-3E18EBE, Order No.
RAC0503011C2 and Model No. CS-E9GFEW, CS-E12GFEW, CS-E18GFEW, Order No. RAC0704001C2.
CS-E7GKEW
OUTDOOR UNIT
CU-2E15GBE
will cause harm or damage, and the seriousness is classified by the following indications.
for future reference.
electrical shock or fire.
done, the set will drop and cause injury.
the set will drop and cause injury.
must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
heat-up or fire at the connection point of terminal, fire or electrical shock.
8. When connecting the piping, do not allow air or any substances other than the specified refrigerant to enter the refrigeration cycle.
Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and possibly result in explosion
and injury.
9. Thickness of copper pipes used must be more than 0.8 mm. Never use copper thinner than 0.8 mm.
electrical appliances. Otherwise, it will cause fire or electrical shock.
may cause fire.
furniture.
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
location for easy maintenance.
2. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries,
permanent connection of this room air conditioner to the power supply is prohibited.
i. Power supply connection to the receptacle using a power plug. Use an approved power plug with earth pin for the connection to the socket.
ii. Power supply connection to a circuit breaker for the permanent component. Use an approved circuit breaker for the permanent connection.
It must be a double pole switch with a minimum 3.5 mm contact gap.
3. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. Take care of
the liquid refrigerant, it may cause frostbite.