CS-E24NKDS, CS-E28NKDS, CU-E24NKD, CU-E28NKD - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-E24NKDS / CS-E28NKDS / CU-E24NKD / CU-E28NKD Service Manual online

10 
Indoor CS-E28NKDS 
Model 
Outdoor CU-E28NKD 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 15.88 (5/8) 
Standard length 
m (ft) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 30 (98.4) 
I/D & O/D Height different 
m (ft) 
20 (65.6) 
Additional Gas Amount 
g/m (oz/ft) 
30 (0.3) 
Piping 
Length for Additional Gas 
m (ft) 
10 (32.8) 
Inner Diameter 
mm  
16.7 
Drain Hose 
Length mm 
650 
Fin Material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
2 × 15 × 21  
Indoor Heat 
Exchanger 
Size (W x H x L) 
mm 
810 × 315 × 25.4 
Fin Material 
 
Aluminium (Blue Coat) 
Fin Type 
 
Corrugated Fin 
Row x Stage x FPI 
 
2 × 30 × 19  
Outdoor Heat 
Exchanger 
Size (W x H x L) 
mm 
38.1 × 762 × 895 
                      865 
Material  
Polypropelene 
Air Filter 
Type  
One-Touch 
Power Supply 
 
Outdoor Power Supply 
Power Supply Cord 
Nil 
Thermostat  
Electronic 
Control 
Protection Device 
 
Electronic Control 
 
DRY BULB 
WET BULB 
Maximum 32 
23 
Cooling 
Minimum 16 
11 
Maximum 30 
 
Indoor Operation Range 
Heating 
Minimum 16 
 
Maximum 43 
26 
Cooling 
Minimum 16 
11 
Maximum 24 
18 
Outdoor Operation Range 
Heating 
Minimum -5 
-6 
1. 
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air 
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 
2. 
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb  
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) 
3. 
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor 2/1°C. 
4. 
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20°C, outdoor -7/-8°C. 
5. 
Specifications are subjected to change without prior notice for further improvement. 
 
 
 