CS-E24GKES, CU-E24GKE, CS-E28GKE, CU-E28GKE - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-E24GKES / CU-E24GKE / CS-E28GKE / CU-E28GKE Service Manual online

7
1. Cooling capacities are based on indoor temperature of 27
°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35
°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20
°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6
°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 21
2 x 30 x 19
Size (W x H x L)
mm
810 x 315 x 25.4
38.1 x 762 x 873.8
903.8
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
230
Hz
50
Input Power
W
Cooling; 2.54k (350 ~ 2.95k)
Heating; 3.30k (360 ~ 3.79k)
Starting Current
A
15.3
Running Current
A
Cooling; 11.8
Heating; 15.3
Power Factor
%
Cooling; 94
Heating; 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection
A
15.9
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT