CS-E24DKD, CU-E24DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 20

Read Panasonic CS-E24DKD / CU-E24DKD Service Manual online

ii. Auto Fan Speed
 1. Cooling
 2. Heating
Note:
 a. UP:
  • If move from Lo, the fan speed will be shifted to Maximum 1520 rpm (E24DK).
  • If move from Maximum, the fan speed no change.
  • In up zone, 10 rpm is added for every 10s until Maximum 1520 rpm (E24DK).
 b. DOWN:
  •  The fan speed will be decreased one step every 10 sec. until Minimum 1270 rpm.
 c. 
Current Output Fixed:
  • Maintain at present fan speed.
 d. Instantaneous Maximum:
  • Fan speed will be increased to maximum auto fan speed.
 e. Temperature in ( ) is for Powerful Mode operation.
20
CS-E24DKD CU-E24DKD