CS-E15DKDW, CU-E15DKD, CS-E18DKDW, CU-E18DKD, CS-E21DKDS, CU-E21DKD - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-E15DKDW / CU-E15DKD / CS-E18DKDW / CU-E18DKD / CS-E21DKDS / CU-E21DKD Service Manual online

3.3. CS-E21DKDS CU-E21DKD
Unit
CS-E21DKDS
CU-E21DKD
Cooling Capacity
kW
kcal/h
BTU/h
6.30 (0.90 - 7.10)
5,420 (770 - 6,110)
21,500 (3,070 - 24,200)
Heating Capacity
kW
kcal/h
BTU/h
7.20 (0.90 - 8.50)
6,190 (770 - 7,310)
24,600 (3,070 - 29,000)
Moisture Removal
l/h
Pint/h
3.5
(7.4)
Power Source (Phase, Voltage, Cycle)
ø
V
Hz
Single
220 - 230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 12.5 (440)
Heating; 13.5 (480)
Me
m
3
/min (cfm)
Cooling; 14.4 (510)
Heating; 14.9 (530)
Hi
m
3
/min (cfm)
Cooling; 16.2 (570)
Cooling; 42.8 (1,510)
Heating; 17.3 (610)
Heating; 41.5 (1,460)
dB (A)
Cooling; High 45, Low 37
Cooling; 48
Heating; High 45, Low 37
Heating; 49
Noise Level
Power level dB
Cooling; High 58
Cooling; High 61
Heating; High 58
Heating; High 62
Electrical Data
Input Power
W
Cooling; 2,210 (215 - 2,540)
Heating; 2,100 (245 - 2,750)
Running Current
A
Cooling; 10.4 - 9.9
Heating; 9.7 - 9.3
EER
W/W
Cooling; 2.85 (4.19 - 2.80)
BTU/hW
Cooling; 9.7 (14.3 - 9.5)
COP
W/W
Heating; 3.43 (3.67 - 3.09)
BTU/hW
Heating; 11.7 (12.5 - 10.5)
Starting Current
A
9.7
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
10
CS-E15DKDW CU-E15DKD / CS-E18DKDW CU-E18DKD / CS-E21DKDS CU-E21DKD
Page of 122
Display