CS-CE9JKE, CU-CE9JKE, CS-CE12JKE, CU-CE12JKE - Panasonic Air Conditioner Service Manual (repair manual). Page 7

Read Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual online

7
1. Cooling capacities are based on indoor temperature of 27
°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35
°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6
°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
°C, outdoor 2/1°C
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20
°C, outdoor
-7/-8
°C
5. Specifications are subjected to change without prior notice for further improvement.
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum
32
23
Minimum
16
11
Heating
Maximum
30
Minimum
16
Outdoor Operation Range
Cooling
Maximum
43
26
Minimum
16
11
Heating
Maximum
24
18
Minimum
-15
-6
MODEL
INDOOR
CS-CE9JKE
OUTDOOR
CU-CE9JKE
Page of 84
Display

Click on the first or last page to see other CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE service manuals if exist.