CS-CE9JKE, CU-CE9JKE, CS-CE12JKE, CU-CE12JKE - Panasonic Air Conditioner Service Manual (repair manual). Page 5

Read Panasonic CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE Service Manual online

5
2 Specifications
MODEL
INDOOR
CS-CE9JKE
OUTDOOR
CU-CE9JKE
Performance Test Condition 
EUROVENT
Power Supply
Phase, Hz
Single, 50
V
230
Min.
Mid.
Max.
Cooling
Capacity
kW
0.60
2.60
3.00
BTU/h
Kcal/h
520
2240
2580
Running Current
A
2.8
Input Power
W
125
590
750
Annual Consumption
kWh
295
EER
W/W
4.80
4.41
4.00
Kcal/hW
4.16
3.80
3.44
Power Factor
%
92
Indoor Noise (H / L)
dB-A
39 / 25
Power Level dB
55 / 42
Outdoor Noise (H / L)
dB-A
46 / -
Power Level dB
61 / -
Heating
Capacity
kW
0.60
3.60
5.00
BTU/h
Kcal/h
520
3100
4300
Running Current
A
3.9
Input Power
W
120
835
1.34k
COP
W/W
5.00
4.31
3.73
Kcal/hW
4.33
3.71
3.21
Power Factor
%
93
Indoor Noise (H / L)
dB-A
40 / 27
Power Level dB
56 / 43
Outdoor Noise (H / L)
dB-A
47 / -
Power Level dB
62 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
3.62 / 1.19k / 3.04
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
3.05 / 1.27k / 2.40
Max Current (A) / Max Input Power (W)
6.0 / 1.34k
Starting Current (A)
3.9
Compressor
Type
Hermetic Motor
Motor Type
Brushless (4-poles)
Output Power
W
750
In
door F
a
n
Type
Cross-flow Fan
Material
ASG20K1
Motor Type
Transistor (8-poles)
Input Power
W
47
Output Power
W
40
Speed
Lo
Cool/Fan
rpm
750
Heat
rpm
800
Me
Cool/Fan
rpm
935
Heat
rpm
1015
Hi
Cool/Fan
rpm
1120
Heat
rpm
1230
Page of 84
Display

Click on the first or last page to see other CS-CE9JKE / CU-CE9JKE / CS-CE12JKE / CU-CE12JKE service manuals if exist.