2. Specification 
 
Indoor CS-C7JKD 
Model 
Outdoor CU-C7JKD 
Performance Test Condition 
NEW JIS 
Phase, Hz 
SINGLE, 50 
Power Supply 
V 220  240 
kW 2.00 
2.02 
BTU/h 6820 
6890 
Capacity 
kcal/h 1720 
1740 
Running Current 
3.0 
2.9 
Input Power 
590 
640 
W/W 3.39 
3.15 
EER 
Btu/hW 11.6 
10.8 
Power Factor 
96 
92 
dB-A 
33 / 26 
33 / 26 
Indoor Noise (H / L) 
Power Level dB 
46 / - 
46 / - 
dB-A 
46 / - 
47 / - 
Cooling 
Outdoor Noise (H / L) 
Power Level dB 
61 / - 
62 / - 
Max Current (A) / Max Input Power (W) 
3.4 / 760 
Starting Current (A) 
12.4 
Type  
Hermetic 
Motor 
Motor Type 
 
Induction (2-poles) 
Compressor 
Output Power 
550 
Type  Cross-Flow 
Fan 
Material  
ASG20K1 
Motor Type 
 
Induction (4-poles) 
Input Power 
36.7 - 38.1 
Output Power (I/D / O/D) 
19  
QLo 
rpm 
690 - 690 
Lo 
rpm 
740 - 740 
Me 
rpm 
840 - 840 
Hi 
rpm 
960 - 960 
Indoor Fan 
Speed 
SHi 
rpm 
1050 - 1050 
Type   Propeller 
Fan 
Material  
PP 
Resin 
Motor Type 
 
Induction (6-poles) 
Input Power 
66.0 - 75.0 
Output Power 
30 
Outdoo
r Fa
Speed 
Hi 
rpm 
800 - 830 
Moisture Removal 
L/h (Pt/h) 
1.3 (2.7) 
Lo m
3
/min (ft
3
/min) 
6.1 (215) - 6.1 (215) 
Me m
3
/min (ft
3
/min) 
6.9 (244) - 6.9 (244) 
Hi m
3
/min (ft
3
/min) 
7.9 (279) - 7.9 (279) 
Indoor Airflow 
SHi m
3
/min (ft
3
/min) 
8.6 (305) - 8.6 (305) 
Outdoor Airflow 
Hi 
m
3
/min (ft
3
/min) 
28.8 (1020) - 29.2 (1040) 
Control Device 
 
Capillary tube 
Refrigerant Oil 
cm
3
 
Atmos NM56M or Suniso 4GDID (290) 
Refrigeration Cycle 
Refrigerant Type 
g (oz) 
R22, 450 (15.9) 
Height(I/D / O/D) 
mm (inch) 
290 (11-7/16) 
510 (20-3/32) 
Width (I/D / O/D) 
mm (inch) 
870 (34-9/32) 
650 (25-19/32) 
Dimension 
Depth (I/D / O/D) 
mm (inch) 
204 (8-1/16) 
230 (9-1/16) 
Weight 
Net (I/D / O/D) 
kg (lb) 
9 (20) 
22 (49) 
Pipe Diameter (Liquid / Gas) 
mm (inch) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
7.5 (24.6) 
Length range (min – max) 
m (ft) 
3 ~ 10 (9.8 ~ 32.8) 
I/D & O/D Height different 
m (ft) 
5 (16.4) 
Additional Gas Amount 
g/m (oz/ft) 
10 (0.1) 
Piping 
Length for Additional Gas 
m (ft) 
7.5 (24.6) 
Inner Diameter 
mm  
16 
Drain Hose 
Length mm 
550 
Fin Material 
 
Pre Coat 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
2 x 10 x 17 
Indoor Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 315 x 25.4 
Fin Material 
 
Blue Coated 
Fin Type 
 
Slit Fin 
Row x Stage x FPI 
 
1 x 23 x 17 
Outdoor Heat  
Exchanger 
Size (W x H x L) 
mm 
12.7 x 483 x 578.4 
Material  
Polypropelene 
Air Filter 
Type  
One-touch 
Power Supply 
 
Indoor 
Power Supply Cord 
10 