CS-C7JKD, CS-C9JKD, CS-C12JKD, CU-C7JKD, CU-C9JKD, CU-C12JKD - Panasonic Air Conditioner Service Manual (repair manual). Page 21

Read Panasonic CS-C7JKD / CS-C9JKD / CS-C12JKD / CU-C7JKD / CU-C9JKD / CU-C12JKD Service Manual online

21 
11. Installation 
Instruction 
11.1  Select the Best Location 
11.1.1 Indoor 
Unit 
x  Do not install the unit in excessive oil fume area 
such as kitchen, workshop and etc. 
x  There should not be any heat source or steam 
near the unit. 
x  There should not be any obstacles blocking the air 
circulation. 
x  A place where air circulation in the room is good. 
x  A place where drainage can be easily done. 
x  A place where noise prevention is taken into 
consideration. 
x  Do not install the unit near the door way. 
x  Ensure the spaces indicated by arrows from the 
wall, ceiling, fence or other obstacles. 
x  Recommended installation height for indoor unit 
shall be at least 2.5 m. 
11.1.2 Outdoor 
Unit 
x  If an awning is built over the unit to prevent direct 
sunlight or rain, be careful that heat radiation from 
the condenser is not obstructed. 
x  There should not be any animal or plant which 
could be affected by hot air discharged.  
x  Keep the spaces indicated by arrows from wall, 
ceiling, fence or other obstacles. 
x  Do not place any obstacles which may cause a 
short circuit of the discharged air. 
x  If piping length is over the [piping length for 
additional gas], additional refrigerant should be 
added as shown in the table. 
 
C24JKD
3/8"
1/2"
5/8"
Piping size
Gas Liquid
1/4"
7.5
5
5
3
10
10
7.5
Model
Additional
Refrige-
rant (g/m)
Max.
Eleva-
tion
(m)
Max.
Piping
Length
(m)
Min.
Piping
Length
(m)
C7JKD
C9JKD
C12JKD
C18JKD
Horse
Power
(HP)
Std.
Length
(m)
Piping
Length
for add.
gas (m)
3/4~
1.5HP
5
3
10
10
7.5
5
3
15
10
7.5
20
3
25
20
7.5
20
3
25
30
7.5
2.5HP
2.0~
 
 
Example: For C9*** 
If the unit is installed at 10 m distance, the quantity of 
additional refrigerant should be 25 g….(10-7.5) m x 10 
g/m = 25 g. 
 
 
 
 
 
 
 
 
 
 
 
 
 
11.1.3 
Indoor/Outdoor Unit Installation 
Diagram 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 63