Remove the earth wire from the evaporator. (Fig.7)
−
Release the generator complete wire (green and red).
(Fig.8)
(Fig.8)
−
Remove 2 screws on the right and 1 screw at the left
side of the control board. (Fig.7)
side of the control board. (Fig.7)
−
Press down the hook on the left side of control board.
(Fig.7)
(Fig.7)
−
Then pull out the Control Board Complete from the unit.
(Fig.7)
(Fig.7)
Fig. 9
−
Remove the cross flow fan bushing from the chassis.
(Fig.9)
(Fig.9)
−
Loosen the fan boss screw at the cross flow fan. (Fig.9)
Fig. 10
−
Push up the evaporator and remove cross flow fan by
pulling both cross flow fan and fan motor. (Fig.10)
pulling both cross flow fan and fan motor. (Fig.10)
12.4. Auto OFF/ON Button
•
The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or
mulfunctioning.
mulfunctioning.
•
Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then
release the button.
release the button.
•
User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
mode.
•
To enter various setting mode:
−
Press the “Auto OFF/ON Button” continuously for 5s (“beep” sound is heard) and release.
−
Within 20s, press the “Auto OFF/ON Button” continuously for 5s again (2 “beep” sound is heard) and release.
−
Various setting mode has limit up to 20s. Then return to normal operation.
12.4.1. Toggle Remote Control Signal Receiving Sound
•
Under various setting mode, press the “Auto OFF/ON Button” to toggle the remote control sound.
−
Short “beep”: Turn ON remote control signal receiving sound.
−
Long “beep”: Turn OFF remote control signal receiving sound.
•
After “Auto OFF/ON Button” is pressed, the 20s counter for various setting mode is restarted.
64