Read Panasonic CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE Service Manual online
Outdoor Unit
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
However, it stops immediately with
remote control stop signal.
Overload Protector
• 2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP
characteristic)
(Refer circuit diagram for OLP
characteristic)
Compressor Reverse Rotation
Protection Control
Protection Control
Outdoor Fan Operation Control
• Inner protector.
CU-C75KE / CU-C95KE
CU-C125KE
5
CS-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
Click on the first or last page to see other CS-C75KE / CS-C95KE / CS-C125KE / CU-C75KE / CU-C95KE / CU-C125KE service manuals if exist.