Read Panasonic CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD Service Manual online
2. Norrowing
Vertical Airflow Direction
− During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
− During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
− During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to
10°, 13°, 16°, 19°, 22° under Cooling and Soft Dry operation mode.
3. Narrowing
Horizontal Airflow Direction
− During Anti-dew condensation prevention, Airflow Direction Auto-control angle change form o° - 44° to 14° - 30° under
− During Anti-dew condensation prevention, Airflow Direction Auto-control angle change form o° - 44° to 14° - 30° under
Cooling and Soft Dry operation mode.
− During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 0°, 11°, 22°, 33°, 44° to
14°, 18°, 22°, 26°, 30° under Cooling and Soft Dry operation mode.
22
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
Click on the first or last page to see other CS-C18DKD / CU-C18DKD / CS-C24DKD / CU-C24DKD service manuals if exist.