Read Panasonic CS-BE25TKE / CU-BE25TKE / CS-BE35TKE / CU-BE35TKE / CS-BE50TKE / CU-BE50TKE / CS-TE20TKEW / CU-TE20TKE / CS-TE25TKEW / CU-TE25TKE / CS-TE35TKEW / CU-E35TKE / CS-TE42TKEW / CU-TE42TKE / CS-TZ20TKEW / CU-TZ20TKE / CS-TZ25TKEW / CU-TZ25TKE / CS-TZ35TKEW / CU-TZ35TKE / CS-TZ42TKEW / CU-TZ42TKE / CS-TZ50TKEW / CU-TZ50TKE Service Manual Supplement online
2
1 Heat Only Operation
Effective date will be 1st of April Production model onwards.
Printed in Malaysia
1.1
How to Activate/Deactivate Heat only Operation
AUTO SW
is pressed
Emergency
Operation
Operation
Forced
Cooling
Operation
Cooling
Operation
Forced
Cooling
Operation
Cooling
Operation
Forced
Heating
Operation
Heating
Operation
Remote
Control
Number
Switch
Mode
Control
Number
Switch
Mode
Remote
Control
Receiving
Sound
OFF/ON
Control
Receiving
Sound
OFF/ON
*Operation
Time Check
Mode
Time Check
Mode
No
Setting
Mode
Setting
Mode
Heat Only
Mode
Enable/
Disable
Mode
Enable/
Disable
AC reset code
AC reset code
AC reset code
AC reset code
AC reset code
CHECK
code
Beep
5s
8s
11s
16s
21s
26s
36s
BeepBeep
BeepBeepBeep BeepBeepBeepBeep
Beep
No
The unit will operate under forced cooling
mode continuously if “AC reset” code is
not pressed to activate standby
x
To enable the “Heat Only” mode, press the AUTO OFF/ON SW for more than 8s and less than 11s, “Beep Beep”
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A short
“Beep” sound will be heard. “Heat Only” mode is now enable.
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A short
“Beep” sound will be heard. “Heat Only” mode is now enable.
x
To disable the “Heat Only” mode, press the AUTO OFF/ON SW for more than 8s and less than 11s, “Beep Beep”
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A long
“Beep” sound will be heard. “Heat Only” mode is now disable.
sound will be heard, then release the AUTO OFF/ON SW and press remote controller CHECK button. A long
“Beep” sound will be heard. “Heat Only” mode is now disable.
x
To pump down the unit during Heat Only Operation press AUTO switch for 5 seconds.
1.2
Operation mode during Heating Only Operation
x
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Deactivated.
Operation
Mode
Heating Only Operation Mode Activated
Heating Only Operation Mode Deactivated
AUTO
After 30s sampling, regardless of the indoor intake or
outdoor intake temperature judgment, the unit will run
Heating operation.
outdoor intake temperature judgment, the unit will run
Heating operation.
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting and
Indoor Intake Sensor (New Auto Mode) or Outdoor
Intake Sensor (Old Auto Mode).
mode base on remote controller temperature setting and
Indoor Intake Sensor (New Auto Mode) or Outdoor
Intake Sensor (Old Auto Mode).
HEAT
The unit will run Heating operation.
The unit will run Heating operation.
COOL
The unit will stop and Power LED blinking.
The unit will run Cooling operation.
DRY
The unit will stop and Power LED blinking.
The unit will run Cooling Dry operation.
NANOE-G
Stand-alone
The unit will stop and Power LED blinking.
The unit will run Nanoe-G Stand-alone operation.
Force Cooling
The unit will run Force Cooling Operation for
X_CTRYTM [15] minutes
X_CTRYTM [15] minutes
The unit will run Force Cooling operation.
Force Heating
The unit will run Force Heating operation.
The unit will run Force Heating operation.
AUTO
(with Timer)
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, regardless of the indoor
intake or outdoor intake temperature judgment, the unit
will run Heating operation.
Operation. After 30s sampling, regardless of the indoor
intake or outdoor intake temperature judgment, the unit
will run Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller temperature
setting and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller temperature
setting and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
HEAT
(with Timer)
The unit will turn ON by the timer and run Heating
Operation.
Operation.
The unit will turn ON by the timer and run Heating
Operation.
Operation.
COOL
(with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
blinking.
The unit will turn ON by the timer and run Cooling
Operation.
Operation.
DRY
(with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
blinking.
The unit will turn ON by the timer and run Cooling Dry
Operation.
Operation.
Cooling
Test Mode
The unit will stop and Power LED blinking.
The unit will operate according to specify Cooling test
mode operation parameter.
mode operation parameter.
Heating
Test Mode
The unit will operate according to specify Heating test
mode operation parameter.
mode operation parameter.
The unit will operate according to specify Heating test
mode operation parameter.
mode operation parameter.
Display