CS-A9CKPG, CU-A9CKP6G, CS-A12CKPG, CU-A12CKP6G (serv.man2) - Panasonic Air Conditioner Service Manual Supplement (repair manual). Page 18

Read Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) Service Manual Supplement online

Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
  • Purpose of this operation is to provide quite cooling operation compare to normal operation.
  • When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
  • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
  • Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).
  • Manual Airflow Direction:-
  − RPM control during Lo cool
  − RPM control during Hi & Me cool
  • Auto Airflow Direction:-
  • Quiet Mode Operation will stop if:-
  − Quiet mode button is pressed again.
  − Stopped by ON/OFF switch.
  − Timer OFF activates.
  − Powerful mode button is pressed.
  − When change mode to Air Circulation mode.
18
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Page of 82
Display

Click on the first or last page to see other CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) service manuals if exist.