CS-A24BD, CS-A28BD, CS-A34BD, CS-A43BD, CS-A50BD, CU-A24BB, CU-A28BB, CU-A34BB, CU-A43BB, CU-A50BB, CU-C24BB, CU-C28BB, CU-C34BB, CU-C43BB, CU-C50BB - Panasonic Air Conditioner Service Manual (repair manual). Page 14

Read Panasonic CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB Service Manual online

ELECTRICAL DATA (50Hz)
3.7 CS-A50BD3P / CU-A50BBP8
ITEM / MODEL
Indoor Unit
Outdoor unit
Main Body
CS-A50BD3P
CU-A50BBP8
Cooling Capacity
kW
14.50
(BTU/h)
(49,400)
Heating Capacity
kW
15.70
(BTU/h)
(53,500)
Refrigerant Charge-less
m
30
Standard Air Volume for High Medium and
Low Speed
m
3
/min
Hi 45
Hi 86
cfm
Hi 1589
3036
External Static Pressure
mmAq
Hi 5 Me 4 Lo 3
-
Pa
Hi 49 Me 39 Lo 29
Air Inlet
Backward Suction
Rear sided Suction
Air Outlet
Front blow-out
Front blow-out
Outside Dimension (H x W x D)
mm
270 x (1500 + 100) x 650
1220 x 1100 x 320
Net Weight
kg (lbs)
56 (123)
116 (256)
Piping
Connection
Refrigerant
Gas
mm (inch)
O.D Ø 19.05 (3/4) Flared Type
Liquid
mm (inch)
O.D Ø 9.52 (3/8) Flared Type
Drain
mm
Female screw RC1 (PT1)
I.DØ 20 x 1
Compressor Type, Number of Set
-
Hermetic-1 (Scroll), 1
Starting Method
-
Direct on-line starting
Motor
Type
-
2-pole 3-phase induction motor
Input
kW
-
Cool/Heat 4.56/4.54
Rated Output
kW
-
4.1
Fan
Type, Number of Set
Sirocco fan-4
Prop. fan-2
Air Volume Control
Three-Step and Auto mode
-
(Remote Control)
Motor
Type
4-pole single phase induction motor
6-pole single phase induction motor
Input
kW
0.30
0.25
Rated Output
kW
0.20
0.055X2
Air-heat Exchanger
Louvre-fin type
Louvre-fin type
Refrigerant Control
Capillary tube
Capillary tube
Refrigerant Oil (Charged)
L
-
SONTEX 200LT (2.1)
Refrigerant (Charged)
kg (oz)
-
R-22 5.0 (176)
Running
Adjustment
Control Switch
Wired Remote Control
-
Room Temperature
Thermostat (Main Body)
-
Safety Devices
Internal protector for compressor, Internal thermostat for F.M, Crankcase heater,
High pressure switch, Current Transformer
Noise Level (Sound Pressure)
dB (A)
Hi 45 Lo 42
Cooling 56, Heating 58
 1. Cooling capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temp. 35°C
D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
 2. Heating capacities are based on indoor temp. 20° CD.B (68.0° FD.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
(42.8°F D.B.)
MODEL / ITEM
CS-A50BD3P/CU-A50BBP8
Condition by JIS B 8616
Volts
V
380
400
415
Phase
3N
3N
3N
Input Power
kW
Cool
5.10
5.10
5.10
Heat
5.09
5.09
5.09
Running Current
A
Cool
8.8
8.8
8.8
Heat
8.8
8.8
8.8
Starting Current
A
69
69
69
Power Factor
%
Cool
88
84
81
Heat
88
83
80
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
Power source
AC, 3N~380V, 400V, 415V 50Hz
14
HIDE AWAY TYPE
Page of 127
Display

Click on the first or last page to see other CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB service manuals if exist.