Read Panasonic CS-A24BD / CS-A28BD / CS-A34BD / CS-A43BD / CS-A50BD / CU-A24BB / CU-A28BB / CU-A34BB / CU-A43BB / CU-A50BB / CU-C24BB / CU-C28BB / CU-C34BB / CU-C43BB / CU-C50BB Service Manual online
CS-A24BD3P (CU-A24BBP5)
CS-A28BD3P (CU-A28BBP5, CU-A28BBP8)
CS-A34BD3P (CU-A34BBP5, CU-A34BBP8)
CS-A43BD3P (CU-A43BBP8)
CS-A50BD3P (CU-A50BBP8)
CS-A24BD3P (CU-C24BBP5)
CS-A28BD3P (CU-C28BBP5, CU-C28BBP8)
CS-A34BD3P (CU-C34BBP5, CU-C34BBP8)
CS-A43BD3P (CU-C43BBP8)
CS-A50BD3P (CU-C50BBP8)
automatic when main power supply is switched on.
(Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However, this address setting is only
possible when made proper wiring connection and also Indoor unit should be original virgin unit.
Therefore, please ensure of the address setting.
1. LCD display of wired remote control had not illuminate although the main power supply switch is ‘on’.
2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoor unit cannot be operated.
b. When changing the connection or combination of units due to re-installation etc.
(Because the unit is having automatic address setting during the first one minute.)
Consequently, when initial power supply is ‘on’, there will not be interchangeability of units even of the same type and same
capacity unit. Therefore unable to connect the unit to another system.
6.0HP), the equipment can be installed in limited spaces.
from below, for easier installation under different conditions.
side for adoption to the installation conditions in the
building.
removed in three directions for easier maintenance.
static pressure can be selected according to the condition
of the duct.
HP. The models is ideal for installation in offices, shop and
houses where quiet operation is important.
It aotomatically adjusts the fan speed according to the
indoor temperature.
during wet season.
heating in accordance with operating load in order to
maintain a confortable indoor temperature.
common specification between Cooling only and Heat
Pump models.
The power can be turned on and off at a single touch,
without opening the cover.
in accordance with indoor conditions by switching with main
unit thermistor.
cable supplied as accessories)