5-5. GEAR CASE ASSEMBLY
REPLACEMENT
After removing the base, refer to the figure and
proceed as follows :
proceed as follows :
(1) Open the wash cover
(2) Unscrew the pulsator fixing screw and remove
(2) Unscrew the pulsator fixing screw and remove
the pulsator. (fig. 17)
(3) Unscrew the pulsator pulley fixing bolt and
revolve the pulsator pulley. (fig. 18)
(4) Unscrew and remove the screws fastening the
gear case assembly at the tub. (fig. 19)
To assemble the gear case, reverse the above
disassembly procedure.
disassembly procedure.
NOTE
•
Don’t disassemble three screws fixing the gear
case. Check the assembled condition of the
pulsator packing at the tub hole when you
assembled the gear case assembly. (fig. 20)
case. Check the assembled condition of the
pulsator packing at the tub hole when you
assembled the gear case assembly. (fig. 20)
5-6. PLUNGER VALVE ASSEMBLY
REPLACEMENT
After removing the back cover and setting the knob
for the drain selector to “WASH RINSE”, refer to the
figure and proceed as follows:
for the drain selector to “WASH RINSE”, refer to the
figure and proceed as follows:
(1) Disconnect the plunger valve strap from the
rod. (fig. 21)
(2) Unscrew the plunger valve cover in the
direction of the arrow. (fig. 22)
Fig. 18
Fig. 17
Fig. 19
Fig. 21
Fig. 22
Fig. 20
TUB
PACKING-P
GEAR CARE