7-4. ERROR DISPLAY
If you press the [Start/Pause] button when an error in displayed, any error except S/W ERROR will
disappear and the machine will change into pause status.
In case of        ,        ,        , if the error is not resolved within 15 sec. In case of other errors, if the
error is not resolved within 4 min. Power will be turned off automatically and the error only will be
blinked. But in the case of       , power will not be turned off.
ERROR
SYMPTOM
CAUSE
WATER INLET
ERROR
Water has not reached to the pre-set level within 4 min.
since inlet valve operated, or water has not reached to
the normal level within 25 min.
1
IMBALANCE 
ERROR
2
DRAIN ERROR
3
OVERFLOW 
ERROR
4
The appliance is tilted.
Laundry is gathered to one side.
Non distributable things are put into the drum.
Water has not drained enough within 8 min.
Water is automatically being pumped out because too
much water is in the tub.
SENSOR PRESSURE
S/W ERROR
5
The sensor pressure switch is out of order.
DOOR OPEN 
ERROR
6
The [Start/Pause] button is pressed with the door open.
The door switch is out of order.
HEATING 
ERROR
7
The thermistor is out of order.
POWER
FAILURE
10
The washer experienced a power failure.
CURRENT
ERROR
8
PWB ASSEMBLY (Main) is out of order
☞ Replace the PWB assembly (Main)
Winding in the MOTOR is short-circuited.
☞ Replace the MOTOR
LOCK 
ERROR
9
The Connector (3-pin, male, white) in the wire harness
is not connected to the Connector (3-pin, female, white)
of MOTOR.
☞ Reconnect or repair the connector
The electric contact between the connectors [3-pin,
male, white in the wire harness and 6-pin, female, white
in the PWB ASSEMBLY (Main]) is bad or unstable.
☞ Reconnect or repair the contact in the connector
The wire harness between the MOTOR and PWB
ASSEMBLY (Main) is cut (open circuited).
The hall sensor is out of order/defective.