Clean the drain pump filter
2
3
2
3
100
1. Open the lower cover
cap
( ) with a tool
such as coin.
Turn the drain plug
( ) to pull out the
hose.
Turn the drain plug
( ) to pull out the
hose.
2. Unplug the drain plug
( ), allowing the water
to flow out. At this time use a vessel to prevent
water from flowing
onto the floor. When water does not flow any
more, turn the pump filter
water from flowing
onto the floor. When water does not flow any
more, turn the pump filter
( ) open to the left.
3. Remove any foreign objects from the
pump filter
( ). After cleaning, turn the
pump filter
( ) clockwise and insert the
drain plug
( ) to the original place.
Close the lower cover cap
( ).
• Allow the water to cool down before cleaning the drain pump filter.
Disassemble the back cover.
Remove the bolt.
Pull out the Rotor.
Unscrew the 2 screws from the tub bracket.
Remove the 6 bolts on the stator.
Unplug the 2 connectors from the stator.
Disassemble the damper hinges from the tub
and base.
Separate the dampers.
NOTE
• Once removed, replace the damper with
new one.