8. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
8-1. Test Equipment
- Color Analyzer (CS-1000, CA-100+(CH.10), CA-210(CH.10))
[ Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module 
O
Change  target  luminance  and  range  of  the  Auto  adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
8-2. Connecting Picture of the Measuring 
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto  controller  or  push  control  R/C  ADJ  Key—>  Enter  the
mode of White-Balance, the pattern will come out.
8-3. Auto-control Interface and Directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight
around is blocked. (illumination is less than 10ux).
(2) In case of PDP: Measure and adjust after sticking the Color
Analyzer (CA-100+, CA210) to the side of the module. 
In  case  of  LCD:  Adhere  closely    the  Color  Analyzer  (
CA210)  to  the  module  less  than  10cm  distance,  keep  it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time  
1)  After  aging  start,  keep  the  power  on  (no  suspension  of
power supply) and heat-run over 15 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto Adjustment Map(RS-232C)
ADJUSTMENT INSTRUCTIONS
0.003
0.003
0.003
[ PC (for communication through RS-232C) ==> UART Baud rate : 115200 bps
3uv
0.329±0.002
0.329±0.002
0.329
y
0.313±0.002
0.313±0.002
0.313
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Warm
0.000
0.000
0.000
3uv
0.293±0.002
0.293±0.002
0.293
y
0.285±0.002
0.285±0.002
0.285
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Medium
0.000
0.000
0.000
3uv
0.283±0.002
0.283±0.002
0.283
y
0.276±0.002
0.276±0.002
0.276
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Cool