ADJUSTMENT INSTRUCTIONS
1. Application Range
This spec sheet is applied to all of the “PU92B” Chassis.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5
c
C  of  temperature  and  65±10%  of  relative  humidity  if
there is no specific designation.
(4)  The  input  voltage  of  the  receiver  must  keep  100~240V,
50/60Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15cC
- In case of keeping module is in the circumstance of 0cC,
it should be placed in the circumstance of above 15cC for
2 hours 
- In case of keeping module is in the circumstance of below
-20cC,  it  should  be  placed  in  the  circumstance  of  above
15cC for 3 hours.
1) Press the POWER ON KEY on R/C for adjustment.
2) Press the ADJ KEY on R/C and enter EZ ADJUST.
Select  “4.  WHITE  PATTERN”  by  using 
D
/
E
(CH  +/-)  and
select “White” by using 
F
/
G
(VOL +/-)
-  Set  is  activated  HEAT  run  without  signal  generator  in  this
mode.
- Single color pattern (RED / BLUE / GREEN) of HEAT RUN
MODE uses to check panel.
Caution:  If  you  turn  on  a  still  screen  more  than  20  minutes
(Especially digital pattern, cross hatch pattern), an after
image  may  be  occur  in  the  black  level  part  of  the
screen.
Caution: Set up “RF mode(noise)” after PCB assembly adjustment.
3. Download
(1)  Execute  ISP  program  “Mstar  ISP  Utility”  and  then  click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message  If  display  “Error”,  Check  connect  computer,  jig,
and set.
(3)  Click  “Connect”  tab.  If  display  “Can’t”  ,  Check  connect
computer, jig, and set.
(4)  Click  “Read”  tab,  and  then  load  download  file(XXXX.bin)
by clicking “Read”
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message.