16-3. Ship-out (Default) mode check
(Instop)
O
After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode. 
16-4. POWER Supply Unit PCB Ass'y Va/Vs
Voltage adjustment
.
[ Caution ] 
Both Vs and Va voltage adjustment are necessary.
(1) Model name: 50/60PK750-UA, 50/60PK950-UA 
(2) Va/Vs Adjustment Procedure
1) Connect  positive(+)  terminal  of  DMM  to  Vs/Va  pin,
connect negative(-) terminal to GND.
2) Turning  ‘  Vs/Va  ’  and  adjust  Vs/Va  voltages  to  a  value
which is written on a right/top label of a module.
( deviation ; ± 0.5V)
[ Caution ] 
Each  Power  Supply  Unit  PCB  assembly  must  be  checked  by
check JIG set.
(Because  power  PCB  Ass°Øy  damages  to  PDP  Module,
especially be careful)
[Caution]
Set up "RF mode(noise)" before a voltage adjustment.
17. USB  Download  (S/W  Update,
*.epk File Download)
(1)  Put the USB Stick to the USB socket 
(2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low,
it didn’t work.
But  your  downloaded  version  is  High,  USB  data  is
automatically detecting
(3) Show the message “Copying files from memory”
(4) Updating is staring.
(5) Updating Completed, The TV will restart automatically.
(6) If  your  TV  is  turned  on,  check  your  updated  version  and
Tool option. (explain the Tool option, next stage)
* If  downloading  version  is  more  high  than  your  TV  have,
TV  can  lost  all  channel  data.  In  this  case,  you  have  to
channel recover. if all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push “OK” button.
(3) Punch in the number. (Each model has their number.)
(4) Completed selecting Tool option.
* After downloading, have to adjust TOOL OPTION again.
1. Push "IN-START" key in service remote controller.
2. Select "Tool Option 1" and Push “OK” button.
3. Punch in the number. (Each model has their number.)
4. Completed selecting Tool option.
- 12 -
Model  
Tool 
Tool 
Tool 
Tool 
Tool 
Tool 
Name
Value 1 Value 2 Value 3 Value 4 Value 5 Value 6
50PZ950-UA 32777
65
7519
7560
14929
857
60PZ950-UA 32781
65
7519
7560
14921
857
50PZ570-UG 32793
65
7519
7560
14921
857
60PZ570-UG 32797
65
7519
7560
14921
857
Page of 75
Display

Click on the first or last page to see other 60PZ950-UA / 60PZ950U-UA (CHASSIS:PU12A) service manuals if exist.