- 10 -
Auto adjustment Map(RS-232C)
13. Adjustment of White Balance
(Manual white Balance)
V  
One of R Gain/ G Gain/ B Gain should be kept on 80, and
others are controlled lowering from 80
(1) Press ‘power on’ of the control R/C, set heat run to white
by pressing and heat run over 15 minutes.(Set: RS-232
Host: PC, Baud Rate: 115200bps, Download: Cortez) 
(2) Zero Calibrate CA-100+, and stick the sensor to the center
of PDP module surface when you adjust.
(3) Double click In-start key on Controlling R/C and get in
‘white balance’.
(4) Set test-pattern on and display inside pattern. Control is
carried out on three color temperature, COOL, MEDIUM,
WARM. (Control is carried out three times.)
(5) When the R/G/B GAIN is 80 on OSD, it is the FULL
DYNAMIC Range of the Module. In order to control white
balance without the saturation of FULL DYNAMIC Range
and DATA, one of R Gain / G Gain / B Gain should be kept
on 80, and other two is controlled lowering from 80.
* Color Temperature: Cool, Medium, Warm
(1) When R GAIN is set to 80
- Control G GAIN and B GAIN by lowering from 80. 
(2) When B GAIN is set to 80
- Control R GAIN and G GAIN by lowering from 80.
(3) When G GAIN is set to 80
- Control R GAIN and B GAIN by lowering from 192.
One of R Gain / G Gain / B Gain should be kept on 80, and
adjust other two lower than 80.
(When R/G/B GAIN are all 80, it is the FULL DYNAMIC
Range of Module) 
14. Input the Shipping Option Data 
1) Push the IN-START key in a Adjust Remocon.
2) Input the Option Number that was specified in the BOM, into
the Shipping area.
3) The work is finished, Push 
V
Key.
15. Set Information(Serial No& Model name)
15-1. Setting up ‘Tool OPTION1,2’
(After setting white balance, this is set)
(1) Press ADJ Key in the R/C for adjustment
(2) Insert Option value by a number key 
(3) Press the Enter Button
15-2. Check the serial number & Model Name
(1) Push the menu button in DTV mode.
- Select the SETUP-> Diagnostics -> To set.
(2) Check the Serial Number.
16. Set factoring condition
(1) This Adjustment is setting factory shipment mode.
(2) Push the IN-STOP key of adjustment remote controller
before the factory shipment.
Type
Baud Rate
115200
Index
R Gain
G Gain
B Gain
R Offset
G Offset
B Offset
Data bit
8
Cmd1 Cmd2
j
a
j
b
j
c
j
d
j
e
j
f
Stop bit
1
Parity
NONE
PD75A/C
Protocol
Setting
Data
Min Value
00(00)
00(00)
00(00)
00(00)
00(00)
00(00)
Max Value
128(80)
128(80)
128(80)
128(80)
128(80)
128(80)
Model
Name
60PF95
Tool
Option1
2379
1977
0
14
2
1
192
Tool
Option2
Area
Option
Option1 Option2 Option3 Option4
Page of 46