Read LG 50PQ100R-ZA (CHASSIS:PP91A) Service Manual online
(6) Select SW file (XXXX.bin) you want, push the “OK” Key.
(7) S/W download process is excuted automatically.
(7) S/W download process is excuted automatically.
4. PCB Assembly Adjustment Method
4-1. Option Adjustment Following BOM
Tool Option
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
* Profile: Must be changed the option value because being
different with some setting value depend on module, inch
and market
and market
* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input the Option Number that was specified in the BOM,
into the Shipping area.
(4) Select “Tool Option/ Area Option” by using
D
/
E
(CH+/-)
key, and press the number key(0~9) consecutively
(5) if it is EU model ( such as 42/50PQ**R-ZA ), select “Area
option” by using
D
/
E
(CH+/-) key , and press the number
key(0~9) consecutively.
ex) If the value of Tool Option1 is 4, input the data using
ex) If the value of Tool Option1 is 4, input the data using
number key “4” (Fig. 3)
Caution: Don’t Push “IN-STOP” key after PCB assembly
adjustment.
(5) EDID D/L Method
After software D/L or PCBA manufacturing, you can
download EDID Data.
When you adjust Tool Option, H6 Model EDID download
process is executed automatically
download EDID Data.
When you adjust Tool Option, H6 Model EDID download
process is executed automatically
* If the model don’t have HDMI 3, HDMI 3 will be disappeared
at OSD Window.
Caution: When you adjust tool option, don’t connect HDMI or D-
sub cable.
If you connect some cable, EDID D/L process will be
failed.
If you connect some cable, EDID D/L process will be
failed.
(6) Adjustment method
Before PCBA check, have to change the Tool option and Area
option
option
[ About PDP
After done all adjustments, Press IN-START button and
compare Tool option and Area option value with its BOM, if it
is correctly same then Change “RF mode” and then unplug
the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
compare Tool option and Area option value with its BOM, if it
is correctly same then Change “RF mode” and then unplug
the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
[ Don’t push The IN-STOP KEY after completing the function
inspection.
[ Appendix - EDID (The Extended Display Identification Data )
Caution: Never Use the cable( HDMI or D-sub cable) for EDID
Writing. Automatically H6 Model EDID download
process is executed when you adjust Tool Option.
process is executed when you adjust Tool Option.
- 9 -
..
3.09
5
..
MODEL : XXXXXX Module : XXXX
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :WW
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :WW
OK
Component SDW
OK
Component HDW
OK
EDID RGB(OK) HDMI1(NG) HDMI2(NG) HDMI3(NG)
Tool OptionW W
4
Area OptionW W
40W
Option 1W
17
Option 2W
40
..
MODEL : XXXXXX Module : XXXX
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :WW
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :WW
OK
Component SDW
OK
Component HDW
OK
EDID RGB(OK) HDMI1(OK) HDMI2(OK) HDMI3(OK)
Tool OptionW W
4
Area OptionW W
40W
Option 1W
17
Option 2W
40
( Fig. 3)
Model
Tool option
Model
Tool option
Model
Tool option
42PQ20R
42PQ70BR
7
42PQ600R
13
50PQ20R
50PQ70BR
8
50PQ600R
14
42PQ30R-TA
42PQ200R
9
50PS80BR
19
50PQ30R-TA
50PQ200R
10
60PS80BR
20
42PQ60R
42PQ300R
11
50PS60FR
21
50PQ60R
50PQ300R
12
42PQ30R-MA
22
50PQ30R-MA
42PQ10R
50PQ10R
25
24
2
1
3
4
5
6
23
Click on the first or last page to see other 50PQ100R-ZA (CHASSIS:PP91A) service manuals if exist.