50PG6900-ZF (CHASSIS:PD84A) - LG TV Service Manual (repair manual). Page 10

Read LG 50PG6900-ZF (CHASSIS:PD84A) Service Manual online

- 10 -
Before adjusting White-balance , the AV ADC should be done.
If  ADC status were “NG”, Need to ADC adjustment.
9. Adjustment of White Balance
9-1. Required Equipment
(1) Remote controller for adjustment 
(2)  Color  Analyzer  (CS-1000,  CA-100,100+,CA-210  or  same
product ) : CH 10 (PDP) 
[ Please adjust CA-210, CA-100+ by CS-1000 before
measuring
(3) Auto W/B adjustment instrument(only for Auto adjustment)
(4) AV Pattern Generator 
(5)  15  Pin  D-Sub  Jack(RGB)  is  connected  to  the  AUTO  W/B
EQUIPMENT.
9-2. AUTO White Balance Process.
Adjust  Process  will  start  by  execute  I2C  Command  (Inner
pattern (0xF3, 0xFF)).
O
Color temperature standards according to CSM and Module
O
CS-1000/CA-100+/CA-210(CH  10)  White  balance
adjustment coordinate and color temperature
9-3. Manual W/B Process
(using adjusts Remote control)
(1) After enter Service Mode by pushing “ADJ” key,
(2) Enter White Pattern off of service mode, and change off ->
on.
(3)  Enter  “W/B  ADJUST”  by  pushing  “
G
”  key  at  “3.  W/B
ADJUST”.
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
9-4. Connecting Picture of the Measuring 
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto  controller  or  push  control  R/C  IN-START  —>    Enter  the
mode of White-Balance, the pattern will come out.
[ Auto-control interface and directions
1. Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2.  Measure  and  adjust  after  sticking  the  Color  Analyzer
(CA-100+, CA210 ) to the side of the module. 
3. Aging time  
After aging start, keep the Power on (no suspension of
power supply) and heat-run over 15 minutes 
O
Auto adjustment Map(I2C)
(1) I2C (100K BPS)
(2) COMMUNICATION START
#Until ACK BIT goes LOW, Repeat it.
(3) Command form.
Command  form  use  DDC2AB  standard  communication
protocol.
a. LEN: DATA BYTE number to send.
b. CMD: Command language that monitor executes.
c. VAL:  FOS DATA
d. CS: Dada’s CHECHSUM that transmit
e. DELAY: 50MS           
f. A: Acknowledge    
<Fig. 6> Connection Diagram of Auto W/B Adjustment
Page of 38
Display