50PG6900-ZF (CHASSIS:PD84A) - LG TV Service Manual (repair manual). Page 6

Read LG 50PG6900-ZF (CHASSIS:PD84A) Service Manual online

- 6 -
1. Application Range
This  spec  sheet  is  applied  all  of  the  PD84A  chassis  by
manufacturing LG TV Plant or sort plants. 
2. Specification
Caution: The module keeping condition
O
The  module  keeping  condition:  The  normal  temperature
condition(more than 15°C)
--> Immediately the line supply.
O
The module keeping condition: 0°C
--> The module must be kept for more than 2 hours at the
normal temperature.
O
The module keeping condition: -20°C
--> The module must be kept for more than 3 hours at the
normal temperature.
O
The case of Gu-mi factory at the winter season.
-->  The  module  must  be  kept  for  more  than  5  minutes  at
the heating zone(40°C~45°C).
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer.
However,  the  use  of  isolation  transformer  will  help  protect
test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5°C  of  temperature  and  65±10%  of  relative  humidity  if
there is no specific designation.
(4)  The  input  voltage  of  the  receiver  must  keep  100~240V,
50/60Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment. 
O
After  RGB  Full  White  in  HEAT-RUN  Mode,  the  receiver
must be operated prior to the adjustment.
O
Enter into HEAT-RUN MODE 
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display PATTERN MODE.
- Set is activated HEAT run without signal generator in this
mode. 
- Caution: If you turn on a still screen more than 20 minutes
(Especially digital pattern, cross hatch pattern), an after
image  may  be  occur  in  the  black  level  part  of  the
screen.
PCB assembly Adjustment Method
Caution:  Using  ‘power  on’  button  of  the  control  R/C,  power  on
TV.
[ ADC Calibration Protocol (RS232)
- Baud rate : 115200 bps
- RS232 Host : PC
- echo : none
3. ADC Adjustment
3-1. Adjustment of AV(CVBS) 
O
Standard  equipment  :  802F  Pattern  Generator.  Master
Pattern Generator(MSPG-925, etc) or same product
O
Required Equipment
1) Remote controller for adjustment 
2)  MSPG-925FS  Pattern  Generator  (Which  has  Video
Signal: 7 Color Bar Pattern shown in Fig. 1).
- Model: 202 / Pattern: 65  EC and FC model use PAL-
BGDHI (composite signal)
(1) Input the Video signal: 7 color Bar signal into AV3.
(2) Set the PSM to Vivid mode in the Picture menu
(3) Press INSTART key on R/C for adjustment.
(4)  Press  the 
G
(Vol.  +)  key  operate  to  set,  then  it  becomes
automatically.
Auto-RGB OK means completed adjustment
ADJUSTMENT INSTRUCTION
 
 
 
 
<Fig. 1> Color Bar Signal
Page of 38
Display

Click on the first or last page to see other 50PG6900-ZF (CHASSIS:PD84A) service manuals if exist.