50PB2RRH-TL (CHASSIS:MF-056L) - LG TV Service Manual (repair manual). Page 11

Read LG 50PB2RRH-TL (CHASSIS:MF-056L) Service Manual online

- 11 -
10. POWER PCB Assy Voltage
Adjustments 
(Va, Vs Voltage adjustments)
10-1. Test Equipment :
D.M.M. 1EA
10-2. Connection Diagram for Measuring
: refer to Fig.15
10-3. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P805, connect
-terminal to GND pin of P805.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(deviation; 
±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P805, connect
-terminal to GND pin of P805.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  right/top.
(deviation ; 
±0.5V)
11. EDID (The Extended Display
Identification Data)/ DDC (Display
Data Channel) download
11-1. Required Test Equipment
1) Adjusting PC with S/W for writing EDID Data.
(S/W : EDID TESTER Ver.2.5)
2) A Jig for EDID Download.
3)  Cable  :  Serial(9Pin  or  USB)  to  D-sub  15Pin  cable,  D-sub
15Pin cable, DVI to HDMI cable.
11-2. Setting of device
11-3. Preparation for Adjustment
1) As above Fig. 16, Connect the Set, EDID Download Jig, PC
& Cable.
2)  Turn  on  the  PC  &  EDID  Download  Jig.  And  Execute  the
S/W : EDID TESTER Ver,2.5.
3) Set up S/W option.
Repeat Number : 5
Device Address : A0
PageByte : 8
4) Power on the Set.
11-4. Sequence of Adjustment
(1) DDC data of Analog-RGB
1) Init the data.
2) Load the EDID data.(Open File).
[Analog(RGB) :
50PC1RR_RGB(B4)0307.ana] (VGA,XGA)
[Digital(HDMI):
50PC1RR_HDMI(DC37)_0307.div] (XGA)
3) Set the S/W as below.
4) Push the “Write Data & Verify”button. And confirm “Yes”.
5) If the writing is finished, you will see the “OK” message.
(Fig. 15) Connection Diagram of power adjustment for measuring.
(Fig. 16) Connection Diagram of DDC download
Open File
Open File
Page of 55
Display