50PB2RRH-TL (CHASSIS:MF-056L) - LG TV Service Manual (repair manual). Page 7

Read LG 50PB2RRH-TL (CHASSIS:MF-056L) Service Manual online

- 7 -
ADJUSTMENT INSTRUCTIONS
1. Application Object
These instructions are applied all of the 50” PLASMA TV, 
MF-056L
Chassis.
2. Note
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5°C  of  temperature  and  65±10%  of  relative  humidity  if
there is no specific designation.
(4)  The  input  voltage  of  the  receiver  must  keep  100-220V~,
50/60Hz.
(5) The receiver must be operated for about 15 minutes prior
to the adjustment.
O
After  RGB  Full  white  HEAT-RUN  Mode,  the  receiver  must
be operated prior to adjustment.
O
Enter into HEAT-RUN MODE
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display PATTERN MODE.
[ Set is activated HEAT-RUN without signal generator in
this mode.
[ Single color pattern(RED/BLUE/GREEN) of HEAT-RUN 
mode uses to check PANEL.
Caution) If you turn on a still screen more than 20 minutes,
(Especially digital pattern, cross hatch pattern) after
image may be occur in the black level part of the screen.
3. Channel memory
3-1. Setting up the LGIDS
1) Install the LGIDS. (idsinst.exe)
2) After installation, restart your PC.
3) Extract [files.zip] to folder [c:\LGIDS\files].
4) Start LGIDS.
3-2. Channel memory Method 
1)  Select  “PDP”  and  “Hurricane”  on  Model  dialog.  And  check
your  connection  in  Communication  dialog.  (If  your
connection  is  ‘NG’,  then  set  your  PORT.(COM1,2,3,...)
correctly.)
2)  Connect  RS-232C  cable  and  turn  on  the  power.(  Use  the
general RS-232C Serial Cable)
(If your connection has completed, you can see “Ready”.)
[ If  your  set  is  not  an  end  products  but  only  a  board,  you
have  to  make  your  board  to  Stand-by  state  (LED_R).  And
you have to Download in Stand_by power state.
3)  Select  proper  CH_memory  file(*.nvm)  for  each  model  at
[NVRAM Download] 
$ [Write Batch]
Next,  select  proper  binary  file(*.bin)  including  the  CH
information for each model at [NVRAM File].
File name  : H2_CH_Memory_RZ.nvm
4) Click the [Download] button.
It means the completion of the CH memory download if all
items  show  ‘OK’  and  Status  is  changed  by  ‘PASS’  at  the
lower right corner of the window.
5)  If  you  want  to  check  whether  the  CH  information  is
memorized correctly or not, click the [Verify] button. 
And  then  compare  NVRAM  File(*.bin)  with  the  CH
information downloaded.
(Fig. 1)
(Fig. 2)
(1)
(2)
(4)
(3)
(Fig. 3)