6. EYE-Q function check
Step 1) Turn on TV
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds
Step 4) Confirm that R/G/B value is lower than 10 of the
“Raw Data (R: G: B: )” .
If after 6 seconds, R/G/B value is not lower than 10,
replace Eye Q II sensor
replace Eye Q II sensor
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds
Step 6) Confirm that “B. Light(xxx)” value increases from 0.
If change is not seen, replace Eye Q II sensor
< step 2> < step 3> < step 4>
< step 5> < step 6>
7.1 Method
- Check that Power Cord is fully inserted to the set
(If loose, re-insert)
- Unit w/ fully inserted power cord and A/V arrives to the auto-
check process.
- Connect D-terminal AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator
- If OK, changeover to I/P check automatically
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator
- If OK, changeover to I/P check automatically
(Remove CORD,A/V from AV Jack Box)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator
- If OK, Good lamp will lit up and the stopper will allow the
- If NG, Buzzer will sound to inform the operator
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
7.2 Checkpoint
NEUTRAL
• LEAKAGE CURRENT: At 0.5mArms
Green Eye-Check
Sensor Data:
1
Backlight: 0
O.K
Green Eye-Check
Sensor Data: 215
Backli ght : 100