42PW350R-MA (CHASSIS:PU11A) - LG TV Service Manual (repair manual). Page 11

Read LG 42PW350R-MA (CHASSIS:PU11A) Service Manual online

* Attachment:  White  Balance  adjustment  coordination  and  color
temperature.
O
Using CS-1000 Equipment. 
- COOL : T=11000K, _uv=0.000, x=0.276 y=0.283 
- MEDIUM  : T=9300K, _uv=0.000, x=0.285 y=0.293 
- WARM  : T=6500K, _uv=0.000, x=0.313 y=0.329 
O
Using CA-210 Equipment. (10 CH)
- Contras value : 216 Gray
- Brighness spec.
6. Test of RS-232C control.
- Press In-Start button of Service Remocon then set the “4.Baud
Rate” to 115200. Then check RS-232C control and 
7. Selection of Country option.
model  (Not  allowed  Korean  model).  It  is  selection  of  Country
about Rating and Time Zone.
(1) Models: All  models  which  PB82C  Chassis  (See  the  first
page.) 
(2) Press “In-Start” button of Service Remocon, then enter the
“Option” Menu with “PIP CH-“ Button 
(3) Select  one  of  these  three  (USA,  CANADA,  MEXICO)
defends on its market using “Vol. +/-“button.
Caution : Don’t  push  The  INSTOP  KEY  after  completing  the
function inspection
Caution : Inspection only PAL M / NTSC
8. GND and ESD Testing
8-1. Prepare GND and ESD Testing.
- Check the connection between set and power cord
8-2. Operate GND and ESD auto-test.
(1) Fully  connected  (Between  set  and  power  cord)  set  enter
the Auto-test sequence.
(2) Connect D-Jack AV jack test equipment.
(3) Turn on Auto-controller(GWS103-4)
(4) Start Auto GND test.
(5) If its result is NG, then notice with buzzer.
(6) If its result is OK, then automatically it turns to ESD Test.
(7) Operate ESD test
(8) If its result is NG, then notice with buzzer.
(9) If  its  result  is  OK,  then  process  next  steps.  Notice  it  with
Good lamp and STOPER Down.
8-3. Check Items.
(1) Test Voltage 
GND: 1.5KV/min at 100mA
Signal: 3KV/min at 100mA
(2) Test time: just 1 second.
(3) Test point
- GND test: Test  between  Power  cord  GND  and  Signal
cable metal GND.
- ESD test: Test  between  Power  cord  GND  and  Live  and
neutral.
(4) Leakage current: Set to 0.5mA(rms)
9. POWER PCB Ass’y Voltage
Adjustment
(Va/Vs Voltage Adjustment)
(1)Test equipment : D.M.M 1EA
(2) Connection Diagram for Measuring : refer to fig.1 
- 11 -
Color 
Test 
Color Coordination
temperature
Equipment
x
y
COOL
CA-210
0.276
±0.002
0.283
±0.002
MEDIUM
CA-210
0.285
±0.002
0.293
±0.002
WARM
CA-210
0.313
±0.002
0.329
±0.002
Item
Min
Typ Max Unit Remark
White  
49
60
-
cd/m - 100%Window White 
average
Pattern
brightness
- 100IRE(255Gray)
- Picture: Vivid(Medium )
Brightness 
-20
+20
%
- 85IRE(216Gray) 100% 
uniformity
Window White Pattern
- Picture: Vivid(Medium)
< fig.1 : 42 inch Power PCB Assy Voltage adjustment >