32LH7000, 32LH7020, 32LH7030 (CHASSIS:LD91D) - LG TV Service Manual (repair manual). Page 14

Read LG 32LH7000 / 32LH7020 / 32LH7030 (CHASSIS:LD91D) Service Manual online

- 14 -
5. Serial number D/L
• press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 + … + Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex)
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Page of 35