Read LG 19LE5300 (CHASSIS:LA01A) Service Manual online
- 13 -
(5) Reference (White Balance Adj. coordinate and color
temperature)
• Luminance: 216 Gray
• Standard color coordinate and temperature using CS-
• Standard color coordinate and temperature using CS-
1000 (CH14)
• 26/22/19LE5300-UE
•Standard color coordinate and temperature using CA-
1000 (by H/R time)
1000 (by H/R time)
5.4. HDCP SETTING
- HDCP setting is not necessary in Saturn5 model.
5.5 Option selection per country
(1) Overview
- Option selection is only done for models in Non-USA
- Applied model: LA92A Chassis applied None USA
model(CANADA, MEXICO)
(2) Method
1) Press ADJ key on the Adj. R/C, then select Country
Group Menu
2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is
done using +, - KEY
done using +, - KEY
5.6. Tool Option selection
• Method: Press Adj. key on the Adj. R/C, then select Tool
option.
5.7. Ship-out mode check (In-stop)
• After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode.
• After final inspection, Always turn on the Mechanical S/W.
6.1. Method
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process.
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
6.2. Checkpoint
• TEST voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
• TEST time: 1 second
• TEST POINT
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
NEUTRAL
• LEAKAGE CURRENT: At 0.5mArms
Mode
Color Coordination
Temp
∆
UV
x
y
COOL
0.269
0.273
13000K
0.0000
MEDIUM
0.285
0.293
9300K
0.0000
WARM
0.313
0.329
6500K
0.0000
Cool Medium
Warm
H/R Time(Min)
x
y x
y x y
269 273 285 293 313 329
1
0-2
276
285
292
305
315
334
2
3-5
274
282
290
302
313
332
3
6-9
273
280
289
300
312
330
4
10-19
272
278
288
298
311
328
5
20-35
271
276
287
296
310
326
6
36-49
269
274
286
294
309
324
7
50-79
269
273
286
293
308
323
8
80 min over
269
273
285
293
308
323
Model
Tool 1
Tool 2
Tool 3
Tool 4
Tool 5
Menu
19LE5300-UE 4320 8714 52260 2317 3104 2
HDMI
22LE5300-UE 8416 8714 52260 2317 3104 2
HDMI
26LE5300-UE(LGD)
12512 18954
52260 2317 3104 3
HDMI
26LE5300-UE(AUO)
3 HDMI
Click on the first or last page to see other 19LE5300 (CHASSIS:LA01A) service manuals if exist.